EQUIPMENT SAFETY SYSTEMS
75 Naxos Way, Keysborough 3173 Victoria Australia
P: +61 3 8770 6555 E: [email protected]
Genie GEN-5 Series
Installation Manual
REV 2.0
24/09/2020
Model6253 OverWatch
™
Installation Manual
Document # DO001235
|
23 of 24
|
Setting Name
Description
Default
wifi_on_gesture_count
The number of times to cover and uncover the sensor
to enter Wi-Fi mode.
3
wifi_on_gesture_time
The timeout before OverWatch stops waiting for the
next part of the gesture in milliseconds
3000
wifi_on_gesture_initial_time
The timeout after startup before OverWatch stops
waiting for start of the gesture in milliseconds
10000
driving_state_timeout
Mode selection switch timeout
7000
Polarity and Input Style
The table below describes each setting
Setting Name
Description
Default
joystick_drive_forward
Direction of joystick to move EWP forward
forward
joystick_elevate_upward
Direction of joystick to move EWP upward
forward
joystick_neutral_move
Direction of joystick that requires monitoring when in
neutral
forward
elevate_polarity
Direction of signal logic
low
drive_polarity
Direction of signal logic
low
trigger_polarity
Direction of signal logic
low
joystick_polarity
Direction of signal logic
low
neutral_safe
Monitor when no drive mode set
yes
driving_state_input
Direct, timer based or separate joysticks
timer
Bypass
Setting Name
Description
overwatch_state
Redundant
active
test_deadman_state
Test channel enabled for primary cutout
bypassed