Cable Reeler Installation
The cable reeler is used to measure the boom extension to determine the maximum lifting
capacity.
A false N07 fault can occur if the boom jumps off the stow
switch due to pressurising the hydraulic system and without
operating the boom extension control. Ensure the stow switch
arm is correctly adjusted to prevent this error.
Step
Description
Diagram
1.
Drill and tap the holes for the cable
reeler according to the mounting
diagram on page 15.
Mount on the supplied standoffs
using the supplied bolts and
washers.
2.
Drill and tap an M8 hole for the
cable anchor. Ensure the cable
anchor is positioned so the cable
runs in line with the boom.
Mount the cable anchor and attach
the cable.
3.
Drill and tap the M6 holes for the
stow switch trigger bracket.
Mount the stow switch trigger
bracket using the supplied standoffs
using the supplied bolts and
washers.
Ensure the stow switch is pressed
when the boom is retracted.