background image

26

Operation

Operation

5.1 

Manual operation

To switch the connected load manually on or off, proceed 

as follows:

• 

Press and hold down the buttons „+“ and „–“ at the 

same time to exit the automatic mode. “Manuell” 

(”manual mode”) appears in the display.

• 

You can manually switch the connected load on and 

of with the buttons “Aus/Ein” (”off/on”). The current 

switching status is shown in the display: “Ein” for “on” 

and “Aus” for “off”.

• 

You can go back to automatic mode by pressing „+“ or 

„–“. “Auto” appears in the display.

5.2 

Setting switch-on and switch-off 

temperature

For operation in automatic mode, you can set the switch-on 

and switch-off temperature at which the connected device 

will be switched on or off. To do this, proceed as follows:

• 

Make sure if the device is in automatic mode (”Auto” 

is shown in the display).

• 

First press the button “Aus/Ein”(”off/on) briefly to 

make changes.

• 

Now select the switch-on temperature with the “+” 

Содержание UT300

Страница 1: ...Bedienungsanleitung S 2 User manual p 17 Universal Thermostat UT300 ...

Страница 2: ...ischer Verfahren vervielfältigt oder verar beitet werden Es ist möglich dass das vorliegende Handbuch noch drucktechnische Mängel oder Druckfehler aufweist Die Angaben in diesem Handbuch werden jedoch regelmäßig überprüft und Korrekturen in der nächsten Ausgabe vorgenommen Für Fehler technischer oder drucktech nischer Art und ihre Folgen übernehmen wir keine Haftung Alle Warenzeichen und Schutzrec...

Страница 3: ...efahrenhinweise 4 3 Bestimmungsgemäßer Einsatz 8 4 Inbetriebnahme 10 4 1 Montage 10 5 Bedienung 11 5 1 Manueller Betrieb 11 5 2 Ein und Ausschalttemperatur einstellen 11 5 3 Betriebsart Heizen Kühlen wählen 12 6 Wartung und Reinigung 13 7 Technische Daten 14 ...

Страница 4: ...Symbole Achtung Hier wird auf eine Gefahr hingewiesen Hinweis Dieser Abschnitt enthält zusätzliche wichtige Informationen 2 Gefahrenhinweise Bei Sach oder Personenschäden die durch unsachgemäße Handhabung oder Nichtbeachten der Sicherheitshinweise verursacht werden übernehmen wir keine Haftung In solchen Fällen erlischt jeder Gewährleistungsanspruch Für Folgeschäden übernehmen wir keine Haftung Au...

Страница 5: ...on einer Fachkraft prüfen Betreiben Sie das Gerät nur in trockener staubfreier Umgebung und setzen Sie es keinem Einfluss von Feuchtigkeit Vibrationen ständiger Sonnen oder anderer Wärmeeinstrahlung übermäßiger Kälte und keinen mechanischen Belastungen aus Das Gerät ist kein Spielzeug erlauben Sie Kindern nicht damit zu spielen Lassen Sie das Verpackungs material nicht achtlos liegen Plastikfolien...

Страница 6: ...es Gerätes zu einem Brand oder elektrischen Unfall führen Geräte mit elektronischen Netzteilen z B Fernseher Hochvolt LED Leuchtmittel stellen keine ohmschen Lasten dar Sie können Einschaltströme von über 100 A erzeugen Das Schalten solcher Verbraucher führt zu vorzeitigem Verschleiß des Aktors Das Gerät darf nur an eine leicht zugängliche Netzsteckdose angeschlossen werden Bei Gefahr ist das Gerä...

Страница 7: ...rdungen für Menschen und Haustiere führen können Jeder andere Einsatz als der in dieser Bedienungs anleitung beschriebene ist nicht bestimmungsge mäß und führt zu Gewährleistungs und Haftungsausschluss Darüber hinaus ist dies mit Gefahren wie z B Kurzschluss Brand elektrischer Schlag etc verbunden Dies gilt auch für Umbauten und Veränderungen Das Gerät ist ausschließlich für den privaten Gebrauch ...

Страница 8: ...ten Temperaturbereich über einen externen Temperatursensor und ist sowohl für den Heiz als auch für den Kühlbetrieb einsetzbar Der Universal Thermostat kann im Automatik betrieb arbeiten oder manuell geschaltet werden Der Universal Thermostat wird als Stecker Steckdosengerät einfach zwischen Netzsteckdose und Verbraucher gesteckt und kann Verbraucher bis zu einer Leistungsaufnahme von 3 680 W 230 ...

Страница 9: ...us Anzeige Heizen Kühlen Auto Manuell Ein dauerhaft Aus dauerhaft B Wechsel zwischen Aus Einschalttemperatur C Temperaturfühler D Anzeige der aktuellen Temperatur bzw der Ein und Ausschalttemperatur E Manuelle Temperatureinstellung F Steckdose für den anzuschließenden Verbraucher ...

Страница 10: ...n die Steckdose F des Universal Thermostats an Nach einem kurzen Selbsttest schaltet das Gerät in den Automatikmodus und die aktuell gemessene Temperatur am Fühler wird im Display angezeigt Bitte beachten Sie dass bei einer Tastenbetätigung zu nächst nur die Displaybeleuchtung eingeschaltet wird Erst auf die nächste Betätigung bei eingeschalteter Beleuch tung reagiert das Gerät Nach einigen Sekund...

Страница 11: ...t Ein bzw Aus im Display angezeigt Die Rückkehr in den Automatikmodus erfolgt durch Drücken der Taste oder Im Display erscheint Auto 5 2 Ein und Ausschalttemperatur einstellen Für den Automatikbetrieb stellen Sie die Einschalt und Aus schalttemperatur ein bei deren Erreichen das angeschlos sene Gerät ein bzw ausgeschaltet werden soll Dazu gehen Sie wie folgt vor Überprüfen Sie ob sich das Gerät im...

Страница 12: ... Automatikmodus zurück Im Display werden die aktuelle Temperatur am Fühler die ge wählte Betriebsart Heizen oder Kühlen und der aktu elle Schaltzustand Aus Ein angezeigt 5 3 Betriebsart Heizen Kühlen wählen Heizen Soll der Universal Thermostat im Heizbetrieb arbeiten wählen Sie für die Ausschalttemperatur eine höhere Tem peratur als für die Einschalttemperatur Beispiel Einschalttemperatur 15 C Aus...

Страница 13: ...peratur 22 C Ausschalttemperatur 17 C Wird die Einschalttemperatur z B 22 C überschritten wird das Kühlgerät eingeschaltet Wird die Ausschalttemperatur unterschritten z B 17 C wird das Kühlgerät ausgeschaltet 6 Wartung und Reinigung Das Produkt ist für Sie wartungsfrei Überlassen Sie eine Wartung oder Reparatur einer Fachkraft Trennen Sie das Gerät vor einer Reinigung vom Stromnetz Reinigen Sie da...

Страница 14: ...en dadurch angegriffen werden 7 Technische Daten Geräte Kurzbezeichnung UT300 Anwendungsart Thermostat Temperatursensor abgesetzt 2 m Anschlussleitung Sensor Temperaturbereich 40 bis 99 C Betriebsart Heiz oder Kühlbetrieb Ein und Ausschalttemperatur unabhängig voneinander ein stellbar Wirkungsweise Typ 1 B Versorgungsspannung 230 V 50 Hz Stromaufnahme 16 A max Leistungsaufnahme Ruhe betrieb 1 3 W ...

Страница 15: ...ung 2 500 V Schutzklasse I Verschmutzungsgrad 2 Temperatur für Kugeldruck prüfung 125 C Hitze und Feuerwider standskategorie D SELV PELV isolierter Transformator Umgebungstemperatur 10 bis 35 C Abmessungen B x H x T 55 x 134 x 40 mm ohne Stecker Gewicht 225 g Technische Änderungen vorbehalten ...

Страница 16: ...ro und Elektronik Altgeräte über die örtlichen Sammelstellen für Elektronik Altgeräte zu entsorgen Hinweis zur Konformität Das CE Zeichen ist ein Freiverkehrszeichen das sich ausschließlich an die Behörden wendet und keine Zusicherung von Eigenschaften beinhaltet Bei technischen Fragen zum Gerät wenden Sie sich bitte an Ihren Fachhändler ...

Страница 17: ...hout the written consent of the publisher Typographical and printing errors cannot be excluded However the information contained in this manual is reviewed on a regular basis and any necessary corrections will be implemented in the next edi tion We accept no liability for technical or typographical errors or the consequences thereof All trademarks and industrial property rights are acknowledged Pr...

Страница 18: ...d information 19 3 Intended use 23 4 Start up 25 4 1 Mounting 25 5 Operation 26 5 1 Manual operation 26 5 2 Setting switch on and switch off temperature 26 5 3 Select operating mode heating or cooling 27 6 Maintenance and cleaning 28 7 Technical specifications 29 ...

Страница 19: ...anual as well Symbols used Attention This indicates a hazard Please note This section contains important additional information 2 Hazard information We do not assume any liability for damage to property or personal injury caused by improper use or the failure to observe the safety instructions In such cases any claim under warranty is extinguished For consequential damages we assume no liability F...

Страница 20: ...tion If you have any doubts have the device checked by an expert The device may only be operated in dry and dust free environment and must be protected from the effects of moisture vibrations solar or other methods of heat radiation cold and mechanical loads The device is not a toy do not allow children to play with it Do not leave packaging material lying around plastic films bags pieces of polys...

Страница 21: ...ty specified for the device Exceeding this capacity could lead to the destruction of the device to a fire or to an electrical accident Devices with electronic power supply units e g TV or high voltage LED light sources are no ohmic loads They can generate inrush currents with more than 100 A Switching such kind of loads may lead to premature wear of the actuator The device may only be connected to...

Страница 22: ...device e g replacing light bulbs Always lay cables in such a way that they do not become a risk to people and domestic animals Using the device for any purpose other than that described in this operating manual does not fall within the scope of intended use and shall invalidate any warranty or liability This also lead to short circuits fires or electric shocks This also applies to any conversion o...

Страница 23: ...erature data within a large temperature range using and external temperature sensor and can be used for heating and cooling applications The device can be operated in automatic mode or switched manually It is simply plugged between the socket outlet and the connected load and can switch the connected devices with a power consumption of up to 3 680 W 230 V 16 A The set temperature data is retained ...

Страница 24: ...ng Auto automatic mode Manuell manual mode Ein permanently on Aus permanently off B Switch between switch on and switch off temperature C Temperature sensor D Display of current temperature as well as switch on and switch off temperature E Manual temperature setting F Socket for the load to be connected ...

Страница 25: ... the socket F of the universal thermostat After a short self test the device switches into automatic mode and the currently measured temperature of the sensor is shown in the display Please note that only the display light is switched on if you operate a button for the first time The device reacts after the next button press after the display light has been switched on The display light will be sw...

Страница 26: ...ing status is shown in the display Ein for on and Aus for off You can go back to automatic mode by pressing or Auto appears in the display 5 2 Setting switch on and switch off temperature For operation in automatic mode you can set the switch on and switch off temperature at which the connected device will be switched on or off To do this proceed as follows Make sure if the device is in automatic ...

Страница 27: ... temperature of the sensor the selected operation mode Heizen Kühlen for heating or cooling and the current switching state Aus Ein for off or on 5 3 Select operating mode heating or cooling Heating If you want the universal thermostat to work in heating mode please select a higher temperature for the switch off temperature than for the switch on temperature Example Switch on temperature 15 C Swit...

Страница 28: ...ample Switch on temperature 22 C Switch off temperature 17 C If the temperature exceeds the switch on temperature e g 22 C the cooling device will be switched on If the temperature falls below the switch off temperature e g 17 C the cooling device will be switched off 6 Maintenance and cleaning The product does not require you to carry out any maintenance Enlist the help of an expert to carry out ...

Страница 29: ...e the plastic housing and label 7 Technical specifications Device short description UT300 Type of application thermostat Temperature sensor external 2 m connecting cable Sensor temperature range 40 to 99 C Operating mode heating or cooling operation switch on and switch off temperature can be adjusted separately Method of operation type 1 B Supply voltage 230 V 50 Hz Current consumption 16 A max S...

Страница 30: ...ode S1 Withstand voltage 2 500 V Protection class I Pollution degree 2 Temperature for ball pressure test 125 C Heat and fire resistance category D SELV PELV insulated transformer Ambient temperature 10 to 35 C Dimensions W x H x D 55 x 134 x 40 mm not incl plug Weight 225 g Subject to technical changes ...

Страница 31: ...sed of at local collection points for waste electronic equipment in compliance with the Waste Electrical and Electronic Equipment Directive Information about conformity The CE sign is a free trading sign addressed exclusively to the authorities and does not include any warranty of any properties For technical support please contact your retailer ...

Страница 32: ...Bevollmächtigter des Herstellers Manufacturer s authorised representative eQ 3 AG Maiburger Straße 29 26789 Leer GERMANY www eQ 3 de ...