SERVICE MANUAL EIS 165.3 N/P KW (short version) inglese
Autori: Serralunga M.
14/10/2021
34
NO COPYING IN ANY FORM WITHOUT WRITTEN PERMISSION FROM EPTA QUALITY MANAGEMENT
6. MAIN CABINET FUNCTIONS
6.1
DISPLAY UNIT AND MAIN PARAMETERS
6.2
USE OF LEDS
SIGNAL
MODE
FUNCTION
ON
Compressor
enabled
FLASHING
Anti
‐
short
cycle
delay
enabled
ON
Defrost
enabled
FLASHING.
Drip
time
in
progress
ON
Fans
enabled
FLASHING
Fans
delay
after
defrost
in
progress
ON
An
allarm
is
occurring
F
ON
Continuous
cycle
is
runnirng
ON
Energy
saving
enabled
ON
Light
on
ON
Auxiliary
relay
on
ON
Measurement
unit
FLASHING
Programming
phase
6.3
HOW TO CHANGE A PARAMETER VALUE
To change any parameter, operate as follows:
1) Enter the Programming mode by pressing both
SET
+
DOWN
keys for 3 sec (the “°C” or
“°F” LED will start blinking).
2) Select the required parameter and then press the
SET
key to display its value.
3) Use
UP
or
DOWN
keys to change its value.
4) Press
SET
to store the new value and move to the following parameter.
To exit
: press both
SET
+
UP
keys or wait for 15 sec without pressing any key.
NOTE
: the set value is stored even when the procedure is exited by waiting the time-out to
expire.
1
2
3
5
4
1.
Light
switch
2.
Automatic
defrosting
button
3.
Button
to
show
set
temperature
4.
Button
to
decrease
temperature
5.
Button
to
increase
temperature