SERVICE MANUAL EIS 165.3 N/P KW (short version) inglese
Autori: Serralunga M.
14/10/2021
23
NO COPYING IN ANY FORM WITHOUT WRITTEN PERMISSION FROM EPTA QUALITY MANAGEMENT
5.15
REPLACEMENT OF POWER CORD REPLACING
1 – Remove the lateral clips (
C
).
2 – Disconnect the rear connector (
D
).
3 – Remove the electronic controller.
5.16
REPLACEMENT OF LED BARS
ELECTRONIC BALLAST
LED BARS
5.17
REPLACEMENT OF TEMPERATURE SWITCH
1) Unscrew and remove upper command panel.
2) Disconnect and remove the temperature switch
-
Epta code for ballast
: I3305398
-
Model
: EL.BALLAST LPV 100-24
-
Epta code for ballast
: I3305723
-
Model
: EL.BALLAST APV 16-24
-
Epta
code
for
LED
lamp
:
I0225233
–
LED
LAMP
SV
‐
FPP54
‐
3014/50
‐
6500
‐
128416
1
C
C
2
D
Epta code Electronic controller:
52997031
Model:
ELECTRONIC CONTROL DIXELL XR72CH 4N0F9 120VAC