SERVICE MANUAL EIS 165.3 N/P KW (short version) inglese
Autori: Serralunga M.
14/10/2021
3
NO COPYING IN ANY FORM WITHOUT WRITTEN PERMISSION FROM EPTA QUALITY MANAGEMENT
1.
AMOUNT OF REFRIGERANT IN THE EQUIPMENT
The most prominent feature of the EIS 165.3 N/P KW versions is that they use a natural gas: propane
(R290).
MODEL
AMOUNT OF
PROPANE*
[grams]
EIS 165.3 N/P KW
270
(*) The propane refrigerant R290 to be used must be technical-gas rated, with purity grade above 99,5%.
PROPANE IS HEAVIER THAN AIR, WHICH MEANS THAT IT WILL
TEND TO CONCENTRATE NEAR THE FLOOR OF THE ROOM.
The flammability limit percentage (in a volume of air) is between 2,2% and 9,2% (at 25°C and 1bar).
In mass terms:
If the entire amount of refrigerant is released in the chest of a EIS 165.3 N/P KW, this would be a
flammability zone event.
39g/m
3
177g/m
3
Striking will not cause
flames
Striking will not cause
flames
0%
Striking will not cause
flames
100%