RS-485 Serial Interface
Notes:
❏
Handshaking is set through the DIP switches on TM series printers. The choices indicated in
parentheses above are typical choices or a typical range of choices supported by TM series printers.
❏
DR1 > DR2 CS1 > CS2 indicates that:
Channel 1 is HIGH.
Channel 2 is LOW.
❏
DR1 < DR2 CS1 < CS2 indicates that:
Channel 2 is HIGH.
Channel 1 is LOW.
Data transmission:
Bit serial
Synchronization: Asynchronous
Handshaking:
Depends on the DIP switch settings
(DTR/DSR or XON/XOFF control )
Signal levels:
2.0 V to 5.0 V: Logic 1
0.0 V to 0.8 V: Logic 0
Baud rates:
Depends on the settings of the TM series printer
(2400 to 19200)
Data word lengths:
Depends on the settings of the TM series printer
(7 or 8 bits)
Parity settings:
Depends on the settings of the TM series printer
(None, even, odd)
Stop bits:
Depends on the settings of the TM series printer
(1 or more)
Signal levels and communication control functions
CS1
CS2
Function
H
L
Communication is available
L
H
Communication is not available
Содержание TM-U200 Series
Страница 1: ...Confidential Technical manual TM U200 Series Type A AM English 400950100 Copied Date 199 Copied by ...
Страница 6: ...iv Confidential Revision Sheet Revision Page Altered Items and Contents Rev A ...
Страница 72: ...2 30 Mechanism Configuration and Operating Principles Rev A Confidential ...
Страница 172: ...6 Appendix Rev A Confidential Main Circuit Board Parts Layout ...
Страница 176: ...10 Appendix Rev A Confidential ...
Страница 186: ...Rev A Appendix A 20 TM U200 Series Type A AM Technical Manual Confidential ...
Страница 187: ...Confidential SEIKO EPSON CORPORATION Printed in Japan ...