Disassembly
72
4.2.1 Housing Removal
Since this printer has no lower Housing, the Printer Mechanism is exposed
just by removing the Housing.
1.
Open the Printer Cover and set the PG Adjust Lever to (+) position.
2.
Remove 4 screws and remove the Housing.
Figure 4-2. Housing Removal
C H E C K
P O I N T
When removing the Housing, be sure to keep the Housing
out of carriage: Pull the Housing toward the printer front
side and lift it upward.
When installing the Housing, be careful not to pinch the cable
with the screw at the rear side of the Housing.
Make sure the Head FFC is set properly inside the rail on the
back of the Housing.
Upper Housing