SC-T7000 series/SC-T5000 series/SC-T3000 series
Revision B
ADJUSTMENT
Other Printer Checks and Adjustments
279
Confidential
4.15.4 Motor Measurement & Automatic Adjustment
The measurement adjustment can be made for the following motors individually.
CR MOTOR
Pump motor (PUMP CAP UNIT)
PF MOTOR
ATC MOTOR
Cutter motor
EXECUTION MODE
Normal mode
PROCEDURE
1. Turn the printer ON.
2. Start the Service Program and select
Motor Measurement & Automatic
Adjustment
of the target motor.
3. Click
[Run]
.
Measurement and adjustment are performed automatically.
4. When finished, click
[Finish]
.
5. Turn the printer OFF to finish the adjustment.
Figure 4-80. [Motor Measurement & Automatic Adjustment] Screen
C A U T I O N
If the adjustment is not finished, replace the motor.