![Epson S5U13517P00C100 Скачать руководство пользователя страница 8](http://html.mh-extra.com/html/epson/s5u13517p00c100/s5u13517p00c100_user-manual_108139008.webp)
Installation and Configuration
8
Seiko Epson Corporation
S5U13517P00C100 Evaluation Board
Rev. 1.1
3.2 Configuration Jumpers
The S5U13517P00C100 has 6 jumpers which configure various board settings. The jumper positions for each
function are shown below.
J1, J2, J3 - Power Supplies for the S1D13517
J1, J2, J3 can be used to measure the current consumption of each S1D13517 power supply.
When the jumper is at position 1-2, normal operation is selected.
When no jumper is installed, the current consumption for each power supply can be measured by connecting an
ammeter between pins 1 and 2 of the jumper.
The jumper associated with each power supply is as follows:
J1 for COREVDD
J2 for IOVDD
J3 for PLLVDD
Figure 3-2: Configuration Jumper Locations (J1, J2, J3)
Jumper
Function
Position 1-2
Position 2-3
No Jumper
J1
COREVDD
Normal
—
COREVDD current
measurement
J2
IOVDD
Normal
—
IOVDD current
measurement
J3
PLLVDD
Normal
—
PLLVDD current
measurement
J4
IOVDD source
3.3V
CN1 connector, pin 32
—
J5
24MHz control
24MHz
stop
—
Normal
= Required settings when using S5U13U00P00C100 USB Adapter board
Jumper
Function
Position 1-2
Position 3-4
Position 5-6
J6
Clock source
On board 24MHz
Second oscillator
CLKI pin to GND
J3
J2, J1