RX
-
8581
SA
/
JE
/
NB
Page - 6
MQ372-02
8.2. Description of Registers
8.2.1. Register table
Address
Function
bit 7 bit 6
bit 5
bit 4
bit 3
bit 2
bit 1 bit 0
Remark
0
SEC
!
40
20
10
8
4
2
1
∗
3
1
MIN
!
40
20
10
8
4
2
1
∗
3
2
HOUR
!
!
20
10
8
4
2
1
∗
3
3
WEEK
!
6
5
4
3
2
1
0
∗
3
4
DAY
!
!
20
10
8
4
2
1
∗
3
5
MONTH
!
!
!
10
8
4
2
1
∗
3
6
YEAR
80
40
20
10
8
4
2
1
−
7
RAM
•
•
•
•
•
•
•
•
∗
4
8
MIN Alarm
AE
40
20
10
8
4
2
1
−
9
HOUR Alarm
AE
•
20
10
8
4
2
1
∗
4
WEEK Alarm
6
5
4
3
2
1
0
A
DAY Alarm
AE
•
20
10
8
4
2
1
∗
4
B
Timer Counter 0
128
64
32
16
8
4
2
1
−
C
Timer Counter 1
•
•
•
•
2048
1024
512
256
∗
4
D
Extension Register
TEST WADA USEL
TE
!
!
TSEL1 TSEL0
∗
1,
∗
3,
∗
5
E
Flag Register
!
!
UF
TF
AF
!
VLF
!
∗
1,
∗
2,
∗
3
F
Control Register
!
!
UIE
TIE
AIE
!
STOP RESET
∗
3
Note
When after the initial power-up or when the result of read out the VLF bit is "1" , initialize all registers, before
using the module.
Be sure to avoid entering incorrect date and time data, as clock operations are not guaranteed when the data
or time data is incorrect.
∗
1)
During the initial power-up, the TEST bit is reset to "0"
and the VLF bit is set to "1".
∗
At this point, all other register values are undefined, so be sure to perform a reset before using the module.
∗
2)
Only a "0" can be written to the UF, TF, AF, or VLF bit.
∗
3)
Any bit marked with "
!
" should be used with a value of "0" after initialization.
∗
4)
Any bit marked with "
•
"
is a RAM bit that can be used to read or write any data.
∗
5)
The TEST bit is used by the manufacturer for testing. Be sure to set "0" for this bit when writing.