ETM44E-01
8.2.8. Temperature Data register
Address
Function
bit 7
bit 6
bit 5
bit 4
bit 3
bit 2
bit 1
bit 0
17
TEMP
128
64
32
16
8
4
2
1
1) Temperature Data register
This register can begin to read digital temperature data.
The temperature data are updated in an operation timing of the temperature compensation circuit.
You can make a conversion to a centigrade by temperature data by calculating in the following
expression .
Temperature[
℃
]
=
( TEMP[ 7:0 ] * 2 – 187.19) / 3.218
8.2.9. Backup power supply function register
Address
Function
bit 7
bit 6
bit 5
bit 4
bit 3
bit 2
bit 1
bit 0
18
Backup Function
VDET
OFF
SWOFF
BKSMP1
BKSMP0
This register is a setting
register the voltage detection of VDD
and built-in MOS switch of anti-countercurrent
control .
1) VDETOFF bit (Voltage Detector OFF)
This bit controls the voltage detection circuit of the main power supply VDD.
For details, see "8.
*
. *****Function".
2) SWOFF bit (Switch OFF)
This bit controls the internal P-MOS switch for preventing back flow.
For details, see "8.
*
. *****Function".
3) BKSMP1,
BKSMP0 bit (Backup mode Sampling time)
This bit controls the operation time when to be intermittently driven the VDD voltage detection.
For details, see "8.
*