3. Environment and Installation
28
Part Feeding 7.0 IF-240 Rev.7
3.6.2 Power Connection
CAUTION
■
Before supplying power to the part feeding, check that the distribution voltage is
the same as the nominal voltage.
■
Never disconnect the power cables when the unit is on. Always turn the
machine off and then cut the power.
■
Use PELV (protected extra-low voltage) nominal voltage.
■
Unplug the main power plug when plugging / unplugging the cord.
Figure 3-6: Power Connection
Pin
Signal description
Cable
(1)
24VDC PELV S-Power
1
(2)
0V GND S-Power
2
(3)
24VDC PELV Power
3
(4)
0V GND Power
4
(5)
EARTH
PE
Connector type (on IF-240 side): M16, 5 Poles, male
In case of all functions working simultaneously (vibration, backlight, outputs), the current
increases to 8A.
Characteristic
Value
Voltage
+24VDC ±5%
Current Power
5A
Current S-Power
3A
■
S-Power is the safety power for the backlight.
Cutting this S-Power ensures that the backlight stays OFF.