5. Maintenance and Component Replacement
Part Feeding 7.0 IF-240 Rev.7
47
Step 9
Unscrew the sensor holder.
Set the sensor at a distance between 1mm to 1.5mm from the sensor plate.
Tighten the 2 screws of the sensor holder.
2 screws I2.5 - 1.2Nm
A red-light signal lights up when the sensor picks up the detection plate.
Step 10
Power ON the feeder and Controller. Open EPSON RC+ and Connect to the Controller.
If you have not already done so, configure the settings to connect the feeder to the
Controller in the EPSON RC+ 7.0-Menu-[Setup]-[System Configuration]. Refer to
section
“2.1 System Configuration”
in the
“Part Feeding 7.0 Introduction & Software”
Manual for further details.
Check the [Purge gate installed] checkbox and click <Apply>.
New parts now can be added from EPSON RC+ 7.0-Menu-[Tools]-[Part Feeding].
CAUTION
■
The [Purge gate installed] setting influences vibration parameters. It is critical
that you check the [Purge gate installed] checkbox prior to adding new Parts in
the Part Feeding dialog. If the checkbox is checked after adding new Parts then
the default vibration parameters will be incorrect and the feeder will not perform
properly.