1. Overview
2
Seiko Epson Corporation
ICDmini Ver. 3.0 User Manual
(Rev 1.0)
1.1 Features
Table 1.1.1 Features of ICDmini Ver. 3.0
Item
Feature
Core CPU supported
S1C17 Core
Host interface
USB Ver. 2.0 (Full speed)
Program break functions
PC break and forced break functions
Target program running time measurement
function
Available
Clock (DCLK) frequency for communicating
with the target MCU
Max. 24 MHz *1
Flash memory programming power supply
Available (Either 7.0 V or 7.5 V output voltage can be selected
from the host computer.)
Target system reset signal output
Available
Target system I/O interface voltage range
1.2 V to 5.5 V (input from the target system) or 3.3 V fixed *2
Target system interface connector
2.54 mm-pitch 10-pin connector *3
Power supply for target system
Available (3.3 V, max. 100 mA)
*1 Clock frequency that is output from the S1C17 MCU’s DCLK pin during debug mode
*2 After power is turned on, the ICD mini Ver. 3.0 is configured so that the I/O interface voltage will be supplied
from the target system. It can be reconfigured from the host computer. For more information, refer to the
manual for the S1C17 Family C Compiler Package Ver. 3.0.0 or later.
*3 A target system connection cable with the target system side connectors compatible with the ICDmini Ver. 1.0,
1.1, and 2.0 is available as an option.
1.2 Operating Environment
The ICDmini Ver. 3.0 requires a PC equipped with a USB port as the host computer. For the operating systems
supported, refer to the manual for the S1C17 Family C Compiler Package Ver. 3.0.0 or later.