5. Firmware Update
ICDmini Ver. 3.0 User Manual
Seiko Epson Corporation
11
(Rev. 1.0)
A display example using Explorer is shown below. In this example, E drive is allocated to the ICDmini Ver.
3.0 as a storage.
Figure 5.3 Example of Drive Allocation to ICDmini Ver. 3.0 (Storage)
(5) Disconnecting the ICDmini Ver. 3.0
After the firmware has been updated, remove the ICDmini Ver. 3.0 device from the host computer by
clicking the Safely Remove Hardware icon in the notification area, at the right of the taskbar, and select
“Eject LPC1XXX IFLASH” in the list of devices that appears. Then unplug the ICDmini Ver. 3.0 from the
host computer.
Figure 5.4 Removing ICDmini Ver. 3.0 (Storage)
(6) Resetting the jumper switch and attaching the bottom cover
Remove the jumper pin set in Step (2) and put it back into the original position. Then attach the bottom
cover paying attention to the direction (align the side of the cover with the notch to the 10-pin connector
side).