Error indicator
If an error occurs, the scanner stops operating and the carriage
lamp
shows the type of error.
Note:
The scanner will turn off the fluorescent lamp if it does not receive any
commands from the computer within 10 minutes.
Operating problems
Problems you may have while using the scanner often involve the
operation of your software and computer. Operation problems
usually occur because of:
❏
Incorrect setup of the interface (see Chapter 3).
Pattern of
light
Problem and solution
F
(Rapidly
flashing )
Cause 1:
The interface setup is wrong, or the
scanner is not properly connected to the
computer.
What to do 1:
Check the interface connection. Then
turn the scanner off and back on to
initialize the scanner again.
Cause 2:
The transportation lock is not released or
the scanner is broken.
What to do 2:
Make sure that the transportation lock is in
the unlocked position; then turn the
scanner off and then back on. If the
scanner still does not operate properly, or
if this error occurs repeatedly, consult your
dealer.
O
Cause:
The lamp is worn out.
What to do:
Consult your dealer.
N
= on,
O
= off,
F
= flashing