Setup & Operation 5. Motion Range
64
G3 Rev.14
5.1.3 Max. Pulse Range of Joint #3
The 0 (zero) pulse position of Joint #3 is the position where the shaft is at its upper limit.
The pulse value is always negative because Joint #3 always moves lower than the 0 pulse
position.
Upper limit: 0 pulse
Model
Joint #3 Stroke
Lower Limit Pulse
G3-**1S*
150 mm
−
1706667
G3-**1C* (Cleanroom-model)
120 mm
−
1365334
For the
Cleanroom-model (G3-**1C*), the motion range set with the Joint #3 mechanical
stop cannot be changed.
5.1.4 Max. Pulse Range of Joint #4
The 0 (zero) pulse position of Joint #4 is the position where the flat near the end of the
shaft faces toward the end of Arm #2. With the 0 pulse as a starting point, the
counterclockwise pulse value is defined as the positive (+) and the clockwise pulse value
is defined as the negative (
-
).
+Y
+X 0 pulse
±
1494221 pulse
Clockwise (
-
value)
Counterclockwise (+value)
NOTE