Maintenance 4. Cable
96
G3 Rev.14
(12) Disconnect 11 connectors on the Arm side.
Connectors X21, X22, X31, X32, X33, X41, X42, X61, X221, X231, X241
X61 is connected to the battery board.
Be sure to keep the connectors of the battery board connected at cables replacement.
Otherwise, the Joint #2, #3, and #4 motors will lose position data and the calibration
must be executed again.
(13) Disconnect the D-sub cable, air tubes, and connector of the brake release switch from
the user plate.
Mounting screws for the D-sub cable are very small. Be sure to keep the screws.
Press the ring on the fitting and pull out the air tube. (ø6
×
2, ø4
×
2)
Be sure to observe the connection for connecting the disconnected parts after
replacement.
(14) Remove the mounting screws for the cable unit and remove the unit from the
Manipulator.
Table Top Mounting
Multiple Mounting
3-M4
×
10
Cable
unit
3-M4
×
12
4-M4
×
10
Cable
unit
3-M4
×
12
NOTE
NOTE
Содержание G3 Series
Страница 1: ...Rev 14 EM183R3623F SCARA ROBOT G3 series MANIPULATOR MANUAL ...
Страница 2: ...MANIPULATOR MANUAL G3 series Rev 14 ...
Страница 8: ...vi G3 Rev 14 ...
Страница 14: ......
Страница 84: ...Setup Operation 5 Motion Range 72 G3 Rev 14 ...
Страница 85: ...Maintenance This volume contains maintenance procedures with safety precautions for G3 series Manipulators ...
Страница 86: ...74 ...
Страница 200: ...Maintenance 15 Maintenance Parts List 188 G3 Rev 14 ...