Status
Cause
Remedy or Status
Set
Direction
to
Pointing Down
,
Pointing Up
,
Angled Up
, or
Angled Down
when the projector is installed in a direction
which is not horizontal.
Press the [Menu] button >
Extended
>
Direction
Filter Airflow Error
Check the following two points.
•
Check that the air filter and air exhaust vent are clear, and that the projector is not positioned against a wall.
•
If the air filter is clogged, remove the power plug from the electrical outlet after turning off the projector, and clean or replace
it.
If the error continues after checking the points above, stop using the projector, disconnect the power cable from the electrical
outlet, and contact your local dealer or the nearest address provided in the Epson Projector Contact List.
s
Auto Iris Error
Cinema filter error
Shutter Error
Power Err. (Ballast)
Stop using the projector, remove the power plug from the electrical outlet, and contact your local dealer or the nearest address
provided in the Epson Projector Contact List.
s
"Epson Projector Contact List"
m
o
n
Indicator is flashing or lit
: Lit
: Flashing
: Off
: Varies according to the projector status
Status
Cause
Remedy or Status
High Temp Warning
(This is not an abnormality. However, if the temperature rises too high again, projection stops automatically.)
•
Check that the air filter and air exhaust vent are clear, and that the projector is not positioned against a wall.
•
If the air filter is clogged, remove the power plug from the electrical outlet, and clean or replace it.
Replace Lamp
The lamp indicated by flashing indicator, lamp 1 or 2, is due for replacement. Replace with a new lamp after turning off the
projector and removing the power plug from the electrical outlet.
If you continue to use the lamp after the replacement period has passed, the possibility that the lamp may explode increases.
Replace it with a new lamp as soon as possible.
We recommend replacing both lamps together to maintain consistent hue and brightness of projected images.
Lamp Warning
Supply System Warning
(Ballast)
Check the following two points after turning off the projector and removing the power plug from the electrical outlet.
•
Remove the lamp indicated by the flashing indicator, lamp 1 or 2, and check if it is cracked.
•
Clean the air filter.