38
Maintenance
Replacing Consumables
Replacing the Air Filter
Replacing the Lamp
Resetting the Lamp Operating Time
Turn off the power, wait
for the cool-down period
to finish (takes
approximately 30
seconds), then
disconnect the power
cable.
Remove the air filter
cover.
Put your finger
under the latch.
Lift up.
Dispose of used air
filters properly in
accordance with your
local regulations.
Air filter frame:
ABS plastic
Air filter:
Polypropylene
Remove the lamp cover
fixing screws.
Securely tighten the
lamp fixing screws.
Insert the new lamp.
Turn off the power, wait
for the cool-down period
to finish (takes
approximately 30
seconds), then disconnect
the power cable.
* Wait until the lamp cools
down (takes
approximately 1 hour).
Make sure that it faces
the correct way.
If the lamp stops working
and needs to be
replaced, there is the
danger that the lamp
may already be broken.
If replacing the lamp of a
projector which has been
installed to the ceiling,
you should always
assume that the lamp is
broken and handle it with
extreme care during
removal. Furthermore,
you should stand to the
side of the projector, not
underneath it.
Press to turn on
the power.
Press to display
the configuration menu.
The lamp operating time
must always be reset after
the lamp has been replaced
with a new one.
When the cumulative
operating time reaches a
certain point, it causes the
replacement warning
message to be displayed.