1 - 87
Chapter 1 Troubleshooting
Epson AcuLaser C2900N
Revision B
Confidential
FIP-1.41 077-107 / 077-108: IOT Duplex Misfeed JAM / IOT Duplex JAM (Duplex Model
only)
Step
Check
Remedy
Yes
No
Possible causative parts:
HARN ASSY DUP RELAY (PL1.2.13)
HARN ASSY L SIDE (PL3.1.18)
HARN ASSY OPTION (PL3.1.20)
ROLL ASSY REGI (PL3.2.9)
ROLL REGI METAL (PL3.2.10)
ROLLER ASSY DUP (PL11.2.9)
SENSOR PHOTO(Regi Sensor) (PL3.2.13)
FUSER UNIT (PL6.1.1)
PWBA MCU (PL8.2.13)
FEEDER ASSY DUP SFP STD (PL11.1.1)
1
Checking the COVER ASSY FRONT MG for latching.
Open and close the COVER ASSY FRONT MG, then check
the latching.
Does the error still occur when printing?
Go to step 2.
End of work.
2
Checking after resetting the fuser unit.
Reseat the fuser unit.
Warning: Start the operation after the fuser unit has cooled
down.
Does the error still occur when printing?
Go to step 3.
End of work.
3
Checking after resetting the Duplex.
Reseat the Duplex.
Does the error still occur when printing?
Go to step 4.
End of work.
4
Checking the DRIVE ASSY EXIT for operation.
Does the DRIVE ASSY EXIT operate properly?
Checked by [Digital Output] - [Exit Motor] on [IOT Diag] of
diagnosis.
During this check, cheat the interlock switch (HARN ASSY
INTERLOCK).
Go to step 5.
Replace FEEDER
ASSY DUP SFP
STD. (Refer to
RRP9.1.)
5
Checking the DRIVE ASSY DUP for operation.
Does the DRIVE ASSY DUP operate properly?
Checked by [Digital Output] - [Duplex Motor] on [IOT Diag]
of diagnosis.
During this check, cheat the interlock switch (HARN ASSY
INTERLOCK).
Go to step 6.
Replace FEEDER
ASSY DUP SFP
STD. (Refer to
RRP9.1.)
6
Checking the Duplex Clutch for operation.
Does the Duplex Clutch operate properly?
Checked by [Digital Output] - [Duplex Clutch] on [IOT Diag]
of diagnosis.
During this check, cheat the interlock switch (HARN ASSY
INTERLOCK).
Go to step 7.
Replace FEEDER
ASSY DUP SFP
STD. (Refer to
RRP9.1.)
7
Checking the SENSOR PHOTO (REGI SENSOR) for
operation.
Does the number on the screen increase by one, every time
the actuator of the SENSOR PHOTO (REGI SENSOR) is
operated?
Checked by [Digital Input] - [Regi Sensor] in [IOT Diagnosis]
of diagnosis.
Go to step 8.
Go to step 10.
Содержание AcuLaser C2900N
Страница 12: ...Confidential CHAPTER 1 Troubleshooting ...
Страница 144: ...1 131 Chapter 1 Troubleshooting Epson AcuLaser C2900N Revision B Confidential Chart Parallelism Perpendicularity ...
Страница 202: ...Confidential CHAPTER 2 Operation of Diagnostic ...
Страница 253: ...Confidential CHAPTER 3 Removal and Replacement Procedures ...
Страница 497: ...Confidential CHAPTER 4 Plug Jack P J Connector Locations ...
Страница 508: ...Confidential CHAPTER 5 Parts List ...
Страница 555: ...Confidential CHAPTER 6 Principles of Operation ...
Страница 567: ...6 10 Chapter 6 Principles of Operation Epson AcuLaser C2900N Revision B Confidential Kmy06007KA ...
Страница 630: ...Confidential CHAPTER 7 Wiring Diagrams and Signal Information ...
Страница 660: ...Confidential CHAPTER 8 Product Specifications ...
Страница 673: ...8 12 Chapter 8 Product Specifications Epson AcuLaser C2900N Revision B Confidential Panel Settings ...
Страница 674: ...8 13 Chapter 8 Product Specifications Epson AcuLaser C2900N Revision B Confidential ...
Страница 675: ...8 14 Chapter 8 Product Specifications Epson AcuLaser C2900N Revision B Confidential PCL Fonts List ...
Страница 676: ...8 15 Chapter 8 Product Specifications Epson AcuLaser C2900N Revision B Confidential PCL Macros List ...
Страница 677: ...8 16 Chapter 8 Product Specifications Epson AcuLaser C2900N Revision B Confidential PS Fonts List ...
Страница 678: ...8 17 Chapter 8 Product Specifications Epson AcuLaser C2900N Revision B Confidential Job History Report ...
Страница 679: ...8 18 Chapter 8 Product Specifications Epson AcuLaser C2900N Revision B Confidential Error History Report ...
Страница 680: ...8 19 Chapter 8 Product Specifications Epson AcuLaser C2900N Revision B Confidential Print Volume Report ...
Страница 681: ...8 20 Chapter 8 Product Specifications Epson AcuLaser C2900N Revision B Confidential Color Regi Chart ...