Indication LED pattern:
Yellow LED ON: Main charge phase with maximum charging current
Yellow LED flashes slowly (1 sec.): U-phase with constant voltage (appr. 80%
charged)
Yellow LED flashes faster (0,3 sec.): Floating charge phase (30 mm. duration)
Green LED ON: Battery 100% charged
After this phase trickle charge follows.
The battery may be permanently connected to the charger. The Cooling fan is
temperature controlled and operates at different speeds. The charging time
depends on the battery capacity. If the battery has been partly discharged, the
charging process will finish sooner.
IMPORTANT SAFETY INSTRUCTIONS
!
Read the manual thoroughly.
!
Charger must be used with the original cables only. Do not change,
shorten, extend or short circuit the cables.
!
Remove the mains plug from the mains first before braking the battery
circuit.
!
Only rechargeable batteries can be used. Do not connect any non-
rechargeable batteries (like dry-cell batteries) to the charger.
!
Charger may be used for correct battery type only. Due to legal regulations,
truck batteries may not be charged while built in the truck and connected to
the electrical board supply system.
!
Do not use the charger inside motor-homes, campers or caravans.
!
Check the charger for cable, housing and connector damages before use.
Do not operate the charger if any damages are present. . There are no
user serviceable parts inside.
!
Do not expose the charger to rain, moisture, direct sunlight or dust..
!
Always disconnect mains after charging and generally when the device is
not in use. During the trickle charge the charger remains attached to the
mains.
!
Always disconnect the mains during a thunderstorm.
ERRORS
1. Check if the battery is properly
connected.
2. Check the Mains
3. Contact your after sales service
Please see the error messages
description of flash pattern below.
Error Messages
No LED lights ON or flash after the
charger has been connected to the
mains.
LED flashes periodically: n-times
Charger temperature sensor failed
Charging time limit has been exceeded (faulty battery/battery aging)
Battery temperature sensor failed or not connected
Charger temperature during the charging process is to high
Battery voltage to high at start of the charging (improper battery)
Battery temperature too low
Battery temperature too high
Charger disconnected from the battery during charging
Bad parameter check sum
Problems with the current measurement offset
Bad parameter values
The current can not be measured/detected
Battery Charging current measurement is out of range
Battery charging current ca not be properly controlled.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Description
Number of
LED flashes
Nominal battery voltage
Nom. Output current
Peak input power
Input voltage
IP Protection Grade
Weight
EPS 600
24V
24V
17A
EPS600
36V
36V
12A
EPS1000
24V
24V
34A
EPS1000
36V
36V
24A
EPS1000
48V
48V
18A
600W / 5A
1200W / 10A
230V - 50/60 HZ
IP 21
2.2 Kgs.
3.9 Kgs.
230V - 50/60 HZ
IP 21
Charger type
TECHNICAL SPECIFICATION