background image

Description of the drawings:

1.

230V plug

2.

Battery connector: 

red = Battery (+) 
black = Battery (-)

3.

Temperature sensor (see the following table)

Any temperature sensors used are only active if the battery charger 
temperature compensation parameters have been set to values other than 
zero. We recommend to fix the temperature sensor to one of the battery 
terminals.

The charger EPS 1001 can be delivered with two separate outputs. The two 
outputs have no galvanic connection. In case of for example 24V charger 
with two outputs, they may serially be connected to a 48V string of batteries 
(each one to 24V string). With this option the batteries get better charge 
equalization. When viewing the charger from the rear, where the battery 
cables exit the housing, the output number one is in the middle and output 
number two at the top.

Pin       Function                                        Pin        Function

1, 2      Temperature sensor                      1, 2        Temperature sensor for output 1

                                                                  3, 4        Temperature sensor for output 2

Single output                                                 
EPS 600/1000

 (Molex type connector) 

Double output EPS 1000

IMPORTANT:

The battery connectors carry large currents. The contacts and the 

whole connector gets very hot if the contacts/connector are not fitted 
properly. We strongly recommend the use of proper tools. The connection 
should be done by qualified personnel.
The charger has to be checked for mechanical damages on the housing or 
cables/connector before use. If any defects are found, then the charger can 
not be put into operation.

EPS 601-X

EPS 601-X

EPS 1001-X