- 26 -
Required
until “CAL Fo” is displayed.
2.
Put the throttle to forward full power
position and press “SELECT” button. “CAL
ST” will be displayed.
3.
Put the throttle to middle (stop) position and
press “SELECT” button. “CAL BA” will be
displayed.
4.
Put the throttle to backward full power
position and press “SELECT” button, the
display will return to normal and the
calibration is completed.
E50
Faulty Charger
If you are not using an ePropulsion charger,
please switch to an ePropulsion charger. If this
issue continues, please contact ePropulsion
service.
E51
Battery
Temperature
Fault
Make sure the environment temperature is
within 0°C to 45°C. Charging will continue when
cell temperature is in that range.
E54
Battery Pack
Over Voltage
Stop the motor and wait until the error message
disappears. If the problem still exists, contact
your dealer for repairing.
E55
Battery Empty
Indicate the battery is empty. The outboard can
probably be restarted at lower speed after the
message is dismissed.
E56
Battery
Charging Over
Current
Switch off and on the motor again and drive at
lower speed. If this issue cannot be solved,
please contact ePropulsion service.
E57
Battery
Discharging
Battery can only work within -20°C to 60°C.
Motor can be started again after the battery