© EPRAD Incorporated
Digital Fault Input Latched
This function configures the Digital 1 Fault and Digital 2 Fault input
flags.
Value
Function
Yes
The Fault remains latched until the Cancel Keys is pressed.
No
The Fault is cleared when the corresponding input turns off.
Fire Stop Input Latched
This function configures the Fire Stop input flags.
Value
Function
Yes
The Fault remains latched until the Cancel Keys is pressed.
No
The Fault is cleared when the Fire Stop input turns off.
Local Alarm Time (MM:SS)
This function configures the local alarm.
Time (mm:ss)
Function
00:00
Disables the local alarm.
99:59
Alarm will sound until cancelled
00:01 to 99:58
Alarm will sound until time expires or cancelled.
User Defined Keys
This allows the user to customize the front panel controls. The eight front panel
keys can be assigned to any of the functions in the table below.
Key
Function
<<blank>>
Key has no function.
Start
Starts or Resumes a program.
Stop
Stops a Program. Press and hold for 5 seconds to abort a program.
Cue
Forces a cue event.
Cancel
Cancels the alarm or clears any ‘latched’ faults.
Bypass
Not used.
Volume Up
Ramps volume up.
Volume Down
Ramps volume down.
Mute
Mutes the sound.
Proj 1 Video
Toggles Projector 1 Video output.
Proj 1 Power
Toggles Projector 1 Power output.
Proj 2 Video
Toggles Projector 2 Video output.
Proj 2 Power
Toggles Projector 2 Power output.
Set Program 1
Sets the program to 1.
Set Program 2
Sets the program to 2.
Set Program 3
Sets the program to 3.
Set Program 4
Sets the program to 4.
Set Program 5
Sets the program to 5.
Set Program 6
Sets the program to 6.
Set Program 7
Sets the program to 7.
Set Program 8
Sets the program to 8.
Set Program 9
Sets the program to 9.
F1
F1 key will be displayed on the Main Status screen if
Web Keys
are enabled.
F2
F2 key will be displayed on the Main Status screen if
Web Keys
are enabled.
F3
F3 key will be displayed on the Main Status screen if
Web Keys
are enabled.
F4
F4 key will be displayed on the Main Status screen if
Web Keys
are enabled.
F5
F5 key will be displayed on the Main Status screen if
Web Keys
are enabled.
F6
F6 key will be displayed on the Main Status screen if
Web Keys
are enabled.
F7
F7 key will be displayed on the Main Status screen if
Web Keys
are enabled.
F8
F8 key will be displayed on the Main Status screen if
Web Keys
are enabled.
Program Abort
Aborts a program (back to idle state). Outputs are not changed.
Pause
Pauses a Program.
29
eCNA-10 Operation and Installation Manual Version 1.270-00
Содержание eCNA-10
Страница 1: ...Model eCNA 10 D Cinema Automation Installation and Operation Manual Version 1 270 00 January 5 2021 ...
Страница 2: ......
Страница 8: ...vi eCNA 10 Operation and Installation Manual Version 1 270 00 ...
Страница 140: ... EPRAD Incorporated 7 System Block Diagram 132 eCNA 10 Operation and Installation Manual Version 1 270 00 ...
Страница 141: ... EPRAD Incorporated System Block Diagram continued 133 eCNA 10 Operation and Installation Manual Version 1 270 00 ...
Страница 142: ... EPRAD Incorporated System Block Diagram continued 134 eCNA 10 Operation and Installation Manual Version 1 270 00 ...
Страница 143: ... EPRAD Incorporated System Block Diagram continued 135 eCNA 10 Operation and Installation Manual Version 1 270 00 ...
Страница 149: ... EPRAD Incorporated 8 3 39445 Board Dimensions 141 eCNA 10 Operation and Installation Manual Version 1 270 00 ...
Страница 154: ... EPRAD Incorporated 8 6 39431 Board Dimensions 146 eCNA 10 Operation and Installation Manual Version 1 270 00 ...