© EPRAD Incorporated
TB5 is the inputs and remote power connections.
TB5
Name
Description / Comment
1
Start A
Software configurable. Default = Remote Start input
2
Start B
3
Stop A
Software configurable. Default = Remote Stop Input
4
Stop B
5
Fire Stop A
Fire Alarm System input
6
Fire Stop B
7
Digital 1 Cue A
Cue input
8
Digital 1 Cue B
9
IN 1 A
These four input are software configurable.
10
IN 1 B
11
IN 2 A
12
IN 2 B
13
IN 3 A
14
IN 3 B
15
IN 4 A
16
IN 4 B
17
(+) 12VDC Power
+12VDC Power (fused at 1/4 amp)
18
(+) 12VDC Power
19
(-) 12VDC Return
20
(-) 12VDC Return
140
eCNA-10 Operation and Installation Manual Version 1.270-00
Содержание eCNA-10
Страница 1: ...Model eCNA 10 D Cinema Automation Installation and Operation Manual Version 1 270 00 January 5 2021 ...
Страница 2: ......
Страница 8: ...vi eCNA 10 Operation and Installation Manual Version 1 270 00 ...
Страница 140: ... EPRAD Incorporated 7 System Block Diagram 132 eCNA 10 Operation and Installation Manual Version 1 270 00 ...
Страница 141: ... EPRAD Incorporated System Block Diagram continued 133 eCNA 10 Operation and Installation Manual Version 1 270 00 ...
Страница 142: ... EPRAD Incorporated System Block Diagram continued 134 eCNA 10 Operation and Installation Manual Version 1 270 00 ...
Страница 143: ... EPRAD Incorporated System Block Diagram continued 135 eCNA 10 Operation and Installation Manual Version 1 270 00 ...
Страница 149: ... EPRAD Incorporated 8 3 39445 Board Dimensions 141 eCNA 10 Operation and Installation Manual Version 1 270 00 ...
Страница 154: ... EPRAD Incorporated 8 6 39431 Board Dimensions 146 eCNA 10 Operation and Installation Manual Version 1 270 00 ...