background image

page | 7

© 2015 Episode®

CONNECT

!

CAUTION: 

All connections and switching must be done with the amplifier turned off. Connect the power 

cord last to ensure that the amplifier is off during all the connections and set up.

RCA Line Level

Use high-quality RCA cables that feature low impedance with adequate shielding and high-quality connectors.

Speaker Outputs

Use 14 or 16 gauge stranded two-conductor speaker wire. Connect the appropriate conductor to each screw 

terminal, observing correct polarity.

!

CAUTION: 

When two subwoofers are connected in parallel, the nominal impedance of each subwoofer 

should not be less than 8Ω.

LS

RS

SUB

CEN

L

R

Switched 

Outlet

+ 12V Trigger

Out

+

-

+

-

+

-

IN

R

L

(LFE)

OUT

OUT

IN

IR

UPDATE

OPERATE

TRIGGER

DC 12V

EA-AMP-SUB-1D-500R

SUB 1

SUB 2

Total Impedance

(Sub 1 + Sub 2) Minimum 4Ω

100-120V AC

220-240V AC

FUSE T8AL/250V

100-120V~60Hz/220-240V~50Hz  500WATTS

Designed and Engineered in USA

Made in China

IN

R

L

(LFE)

OUT

OUT

IN

IR

UPDATE

OPERATE

TRIGGER

DC 12V

EA-AMP-SUB-1D-500R

SUB 1

SUB 2

Total Impedance

(Sub 1 + Sub 2) Minimum 4Ω

100-120V AC

220-240V AC

FUSE T8AL/250V

100-120V~60Hz/220-240V~50Hz  500WATTS

Designed and Engineered in USA

Made in China

EA-AMP-SUB-1D-500R

AV Receiver

EA-AMP-SUB-1D-500R

Single Sub Connections

Dual Sub Connections

8Ω Minimum

8Ω Minimum

4Ω Minimum

Left & Right

Preamp Out or

LFE Sub Out

© 2015 Episode®

Содержание EA-AMP-SUB-1D-500R

Страница 1: ...EA AMP SUB 1D 500R INSTALLATION MANUAL EA AMP SUB 1D 500R ...

Страница 2: ...exit from the apparatus K Only use attachments accessories specified by the manufacturer L Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus When a cart is used use caution when moving the cart apparatus combination to avoid injury from tip over M Unplug this apparatus during lightning storms or when unused for long periods of time N Refe...

Страница 3: ...e RCA input to the left and right front output connections on a receiver or pre amp processor E RCA LINE LEVEL OUTPUTS OUT Connects additional amplifiers F 12V TRIGGER IN OUT 12V TRIGGER IN Turns on the amp when a 12V signal is received from another 12V trigger device 12V TRIGGER OUT Sends a 12V signal to another 12V trigger device G IR PORT Connects IR device H MINI USB PORT Reserved for future u...

Страница 4: ...eaching the last option in the funtion sub menu press to exit to the main menu NOTE The sub menu will scroll continuously in both directions until the knob is pressed to exit once reaching the Menu Exit screen A CROSSOVER 40Hz 250Hz LFE Selects the low pass filter for the amplifier NOTE Set LFE when using the LPF on an AVR DEFAULT LFE B SPEAKER EQ FLAT DUAL8 BSUB12 HSUB10 Selects the EQ mode for t...

Страница 5: ...anges in settings Press and hold knob for 10 seconds to unlock ON Locks controls OFF Allows adjustment of settings DEFAULT OFF I FACTORY RESET Resets all functions to default settings Push the knob to enter the reset menu turn the knob once to select firmware reset then push once more to reset to factory settings NOTE Firmware version is displayed on screen when selected J MENU EXIT SCREEN Press t...

Страница 6: ...ould be allowed above and below the amplifier for optimum performance EA AMP S UB 1D 50 0 Installation Attach ears to the amplifier if mounting into rack Bottom feet on the amplifier chassis may be removed if necessary Minimum of 5 of free air space above and below Minimum of 5 of free air space above and below Minimum of 2 of depth behind unit to accommodate cables and connectors Minimum of 3 fre...

Страница 7: ... of each subwoofer should not be less than 8Ω LS RS SUB CEN L R Switched Outlet 12V Trigger Out IN R L LFE OUT OUT IN IR UPDATE OPERATE TRIGGER DC 12V EA AMP SUB 1D 500R SUB 1 SUB 2 Total Impedance Sub 1 Sub 2 Minimum 4Ω 100 120V AC 220 240V AC FUSE T8AL 250V 100 120V 60Hz 220 240V 50Hz 500WATTS Designed and Engineered in USA Made in China IN R L LFE OUT OUT IN IR UPDATE OPERATE TRIGGER DC 12V EA ...

Страница 8: ...RS SUB CEN LF RF Switched Outlet 12V Trigger Out IN R L LFE OUT OUT IN IR UPDATE OPERATE TRIGGER DC 12V If the receiver does not have a 12V trigger output using a 12V power supply plugged into a switched outlet on the receiver provides the same functionality Connect the appropriate conductor to each screw terminal observing correct polarity 12V DC Tip GND Sleeve ...

Страница 9: ...UPDATE OPERATE TRIGGER DC 12V IN R L LFE OUT OUT IN IR UPDATE OPERATE TRIGGER DC 12V 3 5mm Mono Mini 3 5mm Mono Mini AV Receiver AV Receiver IR Receiver IR Receiver IR Repeater Control System Power Cord Power Cord EA AMP SUB 1D 500R EA AMP SUB 1D 500R IR Repeater Connections Control System Connections 2015 Episode ...

Страница 10: ...e lower frequencies Experiment with different frequency settings until finding one that sounds best When using the LFE input set to LFE and make any crossover adjustments in the preamplifier or receiver crossover settings DUAL8 Optimized for use with Dual 8 In Wall Subwoofer Setting Use Case Value Initial Volume 1 ES SUB IW DUAL8 53 2 ES SUB IW DUAL8 50 Crossover LFE Initial Phase 0 NOTE AVR bass ...

Страница 11: ...o function trouble free Most problems that occur are due to simple issues If having trouble check the list of simple fixes below If the problem persists contact Episode technical support at 866 838 5052 No audio output Audio cable to the source component is not connected properly connection to output or the cable is defective Check connections or replace cable with one that has been verified as go...

Страница 12: ...kmanship under normal conditions of use This warranty shall not apply to products that have been abused modified or disassembled Products to be repaired under this warranty must be returned to a designated service center with an assigned return authorization RA number Contact technical support at support episodeaudio com for an RA number CONTACTING TECHNICAL SUPPORT 866 838 5052 support episodeaud...

Отзывы: