background image

page | 11

© 2015 Episode®

SPECIFICATIONS

Continuous Power Output

250 watts RMS at 8 ohms 

500 watts RMS at 4 ohms (< 0.5% THD)

Input Sensitivity

100 mV for 500W output 4 ohms

Input Impedance

15,000 ohms

S/N Ratio

88 dB (5 kHz bandwidth relative to 500W @ 4 ohms)

Frequency Response

-1.1dB at 300 Hz (Flat EQ, LFE Crossover Setting)

-1.5dB at 20 Hz

Distortion

< 0.2%

Auto On Sensitivity

< 5.5 mV (Left)

< 22 mV (Right)

External Trigger Voltage

12V +/-1.2V no load

10.5 V with 100 mA load

12V Trigger Threshold

2.6 V

Current Limit Threshold

2.7 ohms  (4 ohm minimum nominal speaker load)

Front End Overload

3.6 V RMS (L + R, 20 Volume, 40 Hz Signal, Flat EQ, LFE Crossover)

Dimensions

16.9

"

 W (19

"

 including rack mounts) 

1.75" H (2.1" including feet) 

8.1" D (front switch to rear chassis)

8.9" D (front switch rear speaker connector)

Weight

8.5 lb

Certification

TUV Listed and tested under UL/EN60065 for US and Canada

TROUBLESHOOTING

Episode amplifiers are designed to function trouble-free. Most problems that occur are due to simple issues. If 

having trouble, check the list of simple fixes below. If the problem persists, contact Episode technical support at 

866.838.5052.

No audio output

•  Audio cable to the source component is not connected properly, connection to 

output or the cable is defective. Check connections or replace cable with one 

that has been verified as good.

•  Amplifier is in standby mode and needs to be turned on (blue LED).
•  Check the connections of the speaker wire at both the speaker and amplifier.
•  The level adjustment is turned down. Slowly turn the dial to the right to raise the 

volume.

Hum or buzzing sound is 

heard

•  Check RCA input cables by removing them one at a time and verify connections.

Amplifier will not turn on

•  Ensure the amplifier is plugged into a live outlet.
•  Ensure the power switch on the front panel is on (blue LED).
•  Fuse is blown. Replace with 8AL  fuse type.
•  The power mode may be set to the wrong mode for the system’s configuration 

or setup.

Unable to control menu

•  Ensure amplifier is not in Lock Mode. Hold for 10 seconds to unlock menu.

© 2015 Episode®

Содержание EA-AMP-SUB-1D-500R

Страница 1: ...EA AMP SUB 1D 500R INSTALLATION MANUAL EA AMP SUB 1D 500R ...

Страница 2: ...exit from the apparatus K Only use attachments accessories specified by the manufacturer L Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus When a cart is used use caution when moving the cart apparatus combination to avoid injury from tip over M Unplug this apparatus during lightning storms or when unused for long periods of time N Refe...

Страница 3: ...e RCA input to the left and right front output connections on a receiver or pre amp processor E RCA LINE LEVEL OUTPUTS OUT Connects additional amplifiers F 12V TRIGGER IN OUT 12V TRIGGER IN Turns on the amp when a 12V signal is received from another 12V trigger device 12V TRIGGER OUT Sends a 12V signal to another 12V trigger device G IR PORT Connects IR device H MINI USB PORT Reserved for future u...

Страница 4: ...eaching the last option in the funtion sub menu press to exit to the main menu NOTE The sub menu will scroll continuously in both directions until the knob is pressed to exit once reaching the Menu Exit screen A CROSSOVER 40Hz 250Hz LFE Selects the low pass filter for the amplifier NOTE Set LFE when using the LPF on an AVR DEFAULT LFE B SPEAKER EQ FLAT DUAL8 BSUB12 HSUB10 Selects the EQ mode for t...

Страница 5: ...anges in settings Press and hold knob for 10 seconds to unlock ON Locks controls OFF Allows adjustment of settings DEFAULT OFF I FACTORY RESET Resets all functions to default settings Push the knob to enter the reset menu turn the knob once to select firmware reset then push once more to reset to factory settings NOTE Firmware version is displayed on screen when selected J MENU EXIT SCREEN Press t...

Страница 6: ...ould be allowed above and below the amplifier for optimum performance EA AMP S UB 1D 50 0 Installation Attach ears to the amplifier if mounting into rack Bottom feet on the amplifier chassis may be removed if necessary Minimum of 5 of free air space above and below Minimum of 5 of free air space above and below Minimum of 2 of depth behind unit to accommodate cables and connectors Minimum of 3 fre...

Страница 7: ... of each subwoofer should not be less than 8Ω LS RS SUB CEN L R Switched Outlet 12V Trigger Out IN R L LFE OUT OUT IN IR UPDATE OPERATE TRIGGER DC 12V EA AMP SUB 1D 500R SUB 1 SUB 2 Total Impedance Sub 1 Sub 2 Minimum 4Ω 100 120V AC 220 240V AC FUSE T8AL 250V 100 120V 60Hz 220 240V 50Hz 500WATTS Designed and Engineered in USA Made in China IN R L LFE OUT OUT IN IR UPDATE OPERATE TRIGGER DC 12V EA ...

Страница 8: ...RS SUB CEN LF RF Switched Outlet 12V Trigger Out IN R L LFE OUT OUT IN IR UPDATE OPERATE TRIGGER DC 12V If the receiver does not have a 12V trigger output using a 12V power supply plugged into a switched outlet on the receiver provides the same functionality Connect the appropriate conductor to each screw terminal observing correct polarity 12V DC Tip GND Sleeve ...

Страница 9: ...UPDATE OPERATE TRIGGER DC 12V IN R L LFE OUT OUT IN IR UPDATE OPERATE TRIGGER DC 12V 3 5mm Mono Mini 3 5mm Mono Mini AV Receiver AV Receiver IR Receiver IR Receiver IR Repeater Control System Power Cord Power Cord EA AMP SUB 1D 500R EA AMP SUB 1D 500R IR Repeater Connections Control System Connections 2015 Episode ...

Страница 10: ...e lower frequencies Experiment with different frequency settings until finding one that sounds best When using the LFE input set to LFE and make any crossover adjustments in the preamplifier or receiver crossover settings DUAL8 Optimized for use with Dual 8 In Wall Subwoofer Setting Use Case Value Initial Volume 1 ES SUB IW DUAL8 53 2 ES SUB IW DUAL8 50 Crossover LFE Initial Phase 0 NOTE AVR bass ...

Страница 11: ...o function trouble free Most problems that occur are due to simple issues If having trouble check the list of simple fixes below If the problem persists contact Episode technical support at 866 838 5052 No audio output Audio cable to the source component is not connected properly connection to output or the cable is defective Check connections or replace cable with one that has been verified as go...

Страница 12: ...kmanship under normal conditions of use This warranty shall not apply to products that have been abused modified or disassembled Products to be repaired under this warranty must be returned to a designated service center with an assigned return authorization RA number Contact technical support at support episodeaudio com for an RA number CONTACTING TECHNICAL SUPPORT 866 838 5052 support episodeaud...

Отзывы: