page | 7
© 2019 Episode®
D. Back Button
Press to navigate back a step in the system menu
E. Level Adjustment/Selection Button
Turn to adjust system levels, press to select
F. Power Switch with LED Indicator
Momentary switch for manual control of standby power mode
BLUE
– On
RED
– Standby
REAR PANEL
AT
TENTION ! RISQUE DE CHOC ! ÉL
E
CTRIQUE
PAS OUVRIR !
C
A
UTION
RISK OF ELECTRICAL SHOCK!
DO N
O
T OPEN!
!
Use only a 250V fuse
Employer uniquement aux
un fusible de 250V
U
C
UL
LIFTED
ON
OFF
110 V FUSE
T8AH 250V
230V FUSE
T4A
H250V
118V1
10-120V AC-60H-230W
230V230-240AC-50Hz-230W
SPEAKER OUT
BRIDGE
DIGITAL
IN
CH1
CH1
CH2
CH2
LINE OUT
CH1
CH1
CH2
CH2
IN
LINK
ACT
OUT
LINE IN
TRIGGER
DC 12 V
SERIAL
CONTROL
NETWORK
CONTROL
OUT
CH2
CH1
L
A. Ethernet Port
RJ45 port for connecting an Ethernet Cat5e/6 cable for IP control of the amplifier.
B. RS-232
To communicate with a control system or PC for serial control of the amplifier.
C. 12 Volt Trigger IN and OUT
When 4.5-15 Volts DC are applied to 12V IN, amplifier will turn on. When voltage is dropped, amplifier
turns back off. 12V OUT allows other equipment to be controlled from the same 12V signal.
D. Balanced Inputs 1 & 2
Set-screw connections for sources with balanced output
E. Unbalanced Inputs 1 &2
Unbalanced RCA input connections for connection of sources
F. Unbalanced Loop Out 1 & 2
Unbalanced RCA loop out for connection to other amplifiers
G. Balanced Loop Out 1 & 2
Set-screw balanced loop out for connection to other amplifiers
H. Digital Input/Output ports
Digital input and output ports for Digital sources
I. Speaker Terminals
Note proper positive and negative connections for operating in bridge mode when desired
J. Power Switch
Main amplifier power switch
K. IEC Power Cord
Detachable power for amplifier
L. AC Fuse
Replaceable main power fuse
A
L
D
F
E
B
C
J
K
G
H
I