RFRP-OT OpenTherm® Instructions
Param
Description
Range
Default
HHCH t-1
Maximum set point heating
45 - 85˚C
85˚C
LLCH t-2
Minimum set point heating
10 - HHCH˚C
45˚C
CLI t-3
This allows user to select different climatic
curves for weather compensation. This
only applies to Boilers with an outside
sensor connected.
0.2 - 3.0
1.2
InFL t-4
Influence of room sensor on modulation
of the boiler. Recommended value is 10.
0 - 20
10
HHbO t-5
This is the target setpoint for your CH flow
temperature.
Note: this value must be within the range
of HHCH and LLCH.
HHCH Max
>=ID57
>=LLCH Min
85˚C