43
RFRP-OT OpenTherm® Instructions
It is possible to have 6 CombiPack4-OT controlling 1 OpenTherm® boiler.
To do this it is necessary to make one of the RF1A-OT receivers into a
Hub Receiver. This Hub Receiver will receive data from all of the RFRP-OT
thermostats and relay this information to the boiler via OpenTherm®.
Note: The Hub Receiver should have a wired OpenTherm® connection to
the boiler.
1. Press the Reset button on the receiver that you wish to make
the Hub Receiver – Red and Green lights are both solid.
2. Immediately press and hold the
Connect
and
buttons for 5
seconds, the red light will start blinking.
3. Press the
Connect
button and the Green light will be solid – this is now
the hub receiver.
4. Press the
button to exit to the normal interface.
Controlling an OpenTherm® Boiler with
multiple CombiPack4-OT
Making your RF1A-OT receiver into a Hub Receiver