CDTP2 Room Thermostat 

Hardwired

11. Factory program setting             

5 / 2d

10. Setting the date, time and operating mode

Press the        button once.  ‘Set Date Year’ will appear on the screen.
Press the         or         buttons to adjust the year.  

Press the ‘OK’ button. 

Press the         or         buttons to adjust the month.   Press the ‘OK’ button. 
Press the         or         buttons to adjust the day.  

Press the ‘OK’ button. 

Press the         or         buttons to adjust the hour.  

Press the ‘OK’ button. 

Press the         or         buttons to adjust the minute.   Press the ‘OK’ button. 
Press the         or         buttons to adjust from 5/2d to 7d or 24h mode.
Press the         button or wait 10 seconds and the thermostat will return to 
normal operation.

Set

12. Adjusting the program settings for 5/2d

Press the        button twice.

Programming for Monday to Friday is now selected.

Press the         and         buttons to adjust the P1 time.   Press the ‘OK’ button. 
Press the         and         buttons to adjust the P1 temp.   Press the ‘OK’ button. 
Repeat this process to adjust P2 to P6 times and temperatures. 
Press the         button.

Programming for Saturday to Sunday is now selected.

Press the         and         buttons to adjust the P1 time.   Press the ‘OK’ button. 
Press the         and         buttons to adjust the P1 temp.   Press the ‘OK’ button. 
Repeat this process to adjust P2 to P6 times and temperatures. 
Press the         button to return to automatic mode.

If 7 D mode is selected, you can program each day of the week with 6 
individual times and temperatures. 

If 24H mode is selected, you can only program each day of the week with the 
same 6 times and temperatures.

Press the         and         buttons to adjust the temperature setpoint.
‘Manual’ will appear on the screen. 
Press ‘OK’ or after 10 seconds the thermostat will operate in this 
temporary override.
Press the         button to return to automatic mode.

Set

Set

13. Temporary override (Manual)

Press the         button.   ‘Hold’ will appear on the screen. 
Press the         and        buttons to adjust the temperature setpoint.
Press ‘OK’ or after 10 seconds the thermostat will operate in this 
permanent override.
Press the         button to return to automatic mode.

Press the ‘OK’ and ‘Hold’ buttons for 5 seconds. 
‘0.4˚C’ will appear on the screen. 
Press the up or down buttons to adjust from 0.2, 0.4, 0.6, 0.8 or 1C. 
Press the          button to return to normal operation. 

14. Permanent override (Hold)

15. Adjusting the switching differential               

0.4˚C

Mon-Fri

5/2D

P1

P2

P3

P4

P5

P6

06:30

08:00

12:00

14:00

17:30

22:00

21˚C

18˚C

21˚C

18˚C

21˚C

16˚C

21˚C

18˚C

21˚C

18˚C

21˚C

16˚C

Sat-Sun

08:00

10:00

12:00

14:00

17:30

23:00

Mon-Fri

7D

P1

P2

P3

P4

P5

P6

06:30

08:00

12:00

14:00

17:30

22:00

21˚C

18˚C

21˚C

18˚C

21˚C

16˚C

21˚C

18˚C

21˚C

18˚C

21˚C

16˚C

Sat-Sun

08:00

10:00

12:00

14:00

17:30

23:00

P1

P2

P3

P4

P5

P6

06:30

08:00

12:00

14:00

17:30

22:00

21˚C

18˚C

21˚C

18˚C

21˚C

16˚C

Everyday

24H

Boiler 

Plus

Hold

EPH Controls Ireland

[email protected]    www.ephcontrols.com

EPH Controls UK

[email protected]    www.ephcontrols.co.uk

20180521_CDTP2_OpIns_JW

Normal Mode (Nor)

16. Installer menu

To access the installer menu, you must hold 

OK

 and       for 5 seconds. 

When in the installer menu, press         or         and 

OK 

to navigate and select. 

When the thermostat is in Normal mode, the thermostat will try to reach the 
target temperature after the program changes.  

Example:  Program 1 on the thermostat is 21°C for 06:30am and the room 

temperature is 18°C. The thermostat will start the heating at 06:30am and the 

room temperature will start to increase then. 

To return to main menu, press 

OK 

to select 

Nor

When the thermostat is in Optimum Start mode, the thermostat will try to 
reach the target temperature by the start time of the next switching time. 
This is done by setting the Ti (time interval) on the thermostat in this menu 
to 10, 15 or 20. This will allow the thermostat 10 mins, 15 mins or 20 mins to 
increase the room temperature by 1°C. 
Ti can be set when OS is selected in the installer menu. 
To return to main menu, press 

OK 

to select required

 Ti

To achieve the target temperature when the program starts, the thermostat 
will read:
 

1.  The Room Temperature (RT) 

 

2.  The Setpoint Temperature (ST)

 

3.  The Target Temperature Difference (TTD) is the difference between  

 

  the setpoint temperature and the room temperature .

The time (in minutes) that it will take to overcome (TTD) is called Optimum 
Start Time (OST) and its maximum value is 3 hours = 180 mins. This is 
subtracted from the start time.
As the temperature increases the thermostat will recalculate the OST if the 
temperature is increasing too quickly. 

Optimum Start Mode (OS)

Example when Ti = 20

Program 1 on the thermostat is 21°C for 
06:30am and the room temperature is 18°C. 
The thermostat will start the heating at 
05:30am to reach 21°C for 06:30am @ Ti=20.

Example when Ti = 10

Program 1 on the thermostat is 21°C for 
06:30am and the room temperature is 18°C. 
The thermostat will start the heating at 
06:00am to reach 21°C for 06:30am @ Ti=10.

20˚C

0

20

40

60

80

100

120

140

160

180

O

ptimum S

tar

t T

ime (M

ins)

Target Temperature Difference ˚C

TTD

8

9

7

6

5

4

3

2

1

Optimum Start Control Graph with Ti = 20

0

15

30

45

60

75

90

105

120

135

O

ptimum S

tar

t T

ime (M

ins)

Target Temperature Difference ˚C

TTD

8

9

7

6

5

4

3

2

1

Optimum Start Control Graph with Ti = 15

0

10

20

30

40

50

60

70

80

90

O

ptimum S

tar

t T

ime (M

ins)

Target Temperature Difference ˚C

TTD

8

9

7

6

5

4

3

2

1

Optimum Start Control Graph with Ti = 10

Boiler 

Plus