14 

8. Maintenance                                                           

 

The  following  inspections  and  maintenance  tasks  are  recommended  at  least  two 

times per year for best performance. 

 

Make sure no block on air-flow around the inverter. Clear up any dirt and fragments on 

the radiator. 

 

Check  all  the  naked  wires  to  make  sure  insulation  is  not  damaged  for  serious 

solarization. Frictional wear, dryness, insects or rats, etc. Repair or replace some wires 

if necessary. 

 

Check  and  confirm  that  indicator  and  display  are  consistent  with  required.  Pay 

attention to any troubleshooting or error indication. Take corrective action if necessary. 

 

Confirm that all the terminals have no corrosion, insulation damaged, high temperature, 

or burnt/discolored sign, tighten terminal screws to the suggested torque.   

 

Check for dirt, nesting insects, and corrosion. If so, clear up in time. 

 

Check and confirm that the lightning arrester is in good condition. Replace a new one 

in time to avoid damaging the inverter/charger and even other equipment.   

WARNING

Risk of electric shock! 

Risk of electric shock! Before the above operations, ensure that all the power is turned off. 

The electricity in the capacitances is completely discharged, then follows the corresponding 

inspections and operations. 

Содержание IP1000-11

Страница 1: ...Pure Sine Wave Inverter User Manual IP350 12 22 11 21 IP500 12 22 11 21 IP1000 12 22 11 21 IP1500 12 22 11 21 IP2000 22 42 21 41...

Страница 2: ......

Страница 3: ...TS 1 Important Safety Instructions 1 2 Introduction 3 3 Designations of models 4 4 Wiring 5 5 Functions 7 6 Protection 11 7 Troubleshooting 13 8 Maintenance 14 9 Disclaimer 15 10 Technical Specificati...

Страница 4: ...ep normal inverter operation Use a DC power supply for testing may cause damage to the inverter When the inverter works continuously its surface may become very hot please ensure the air ventilation c...

Страница 5: ...ctric shock don t touch the output port when the inverter is working The output is forbidden to connect to other power sources or grid otherwise the inverter will be damaged The inverter must be turne...

Страница 6: ...electrical isolation Adoption of advanced SPWM technology pure sine wave output Optional output voltage 220 230VAC or 110 120VAC choosing by DIP switch LED indicators for fault status and working stat...

Страница 7: ...1 12VDC 110 120VAC 350W IP350 21 24VDC 110 120VAC 350W IP500 11 12VDC 110 120VAC 500W IP500 21 24VDC 110 120VAC 500W IP1000 11 12VDC 110 120VAC 1000W IP1000 21 24VDC 110 120VAC 1000W IP1500 11 12VDC 1...

Страница 8: ...utput Operation Steps Step 1 Turn the power switch of the inverter to OFF Step 2 Disconnect the input breaker or the fuse between the inverter and battery connect the battery terminals with the red li...

Страница 9: ...the operation state of the inverter and loads Step 6 If there are different types of loads the loads with higher startup current should be turned on firstly such as television After the loads work sta...

Страница 10: ...ication port 4 DC input voltage range 1 USB output port 5VDC 1A DC Input Terminal Negative AC output switch Ventilation Fan 2 Mode switch 5 Grounding Terminal Fault indicator red 6 AC Outlet 3 Working...

Страница 11: ...n the heat sink temperature is higher than 50 or the internal temperature is higher than 50 the fan will turn on automatically When the heat sink temperature is lower than 40 and the internal temperat...

Страница 12: ...models optional The RJ45 interface pin definition is shown below 5 Mode Switch When switch No 1 is on the ON side the output frequency is 60Hz Otherwise it is 50Hz When switch No 2 is on the ON side t...

Страница 13: ...g indicator Fault indicator Buzzer Status Green On Solid Red OFF No Sounding Output is normal Green Slowly Flashing 1 4Hz Red OFF Sounding Input under voltage Green Fast Flashing 1Hz Red OFF Sounding...

Страница 14: ...6V Ui 43 2V Output is OFF Green indicator slowly flashing Buzzer sounds Ui 12 5V Ui 25V Ui 50V Green indicator on solid The output is on Over tem protection and recover Tem T Heat sink T 80 IP1000 T 7...

Страница 15: ...n output overload protection or load short circuit protection is activated the AC output would auto recovery three times the first time delays for 5s the second time delays for 10s and the third time...

Страница 16: ...Adjust the input voltage to restore normally Red indicator slowly flashing Buzzer sounds Overload Reduce the number of AC loads Restart the inverter Red indicator fast flashing Buzzer sounds Short ci...

Страница 17: ...y troubleshooting or error indication Take corrective action if necessary Confirm that all the terminals have no corrosion insulation damaged high temperature or burnt discolored sign tighten terminal...

Страница 18: ...e or use in an inappropriate environment Battery voltage exceeds the input voltage limit of the inverter Damage caused by working environment temperature exceeds the rated range Unauthorized dismantli...

Страница 19: ...sine wave Distortion THD THD 5 THD 3 THD 5 THD 3 Max Efficiency 90 91 91 92 No load current 0 7A 0 5A USB Output Port 5VDC Max 1A Binding post 6mm Overall dimension 214 105 5 57 7mm Mounting dimensio...

Страница 20: ...Resistive load Conventional products don t have this port the port is optional Item IP1000 11 IP1000 12 IP1000 21 IP1000 22 Rated Input Voltage 12VDC 24VDC Input Voltage Range 10 8 16VDC 21 6 32VDC I...

Страница 21: ...3 220VAC 5 230VAC 7 5 Output Frequency 50 60 0 1Hz Output Continuous Power 1200W Output Power 15 min 1500W Surge power 2400W Power factor 0 2 1 VA lower than output continuous power Output Wave Pure s...

Страница 22: ...5VDC Max 1A RS485 Com Port 5VDC 200mA Binding Post 6mm Overall Dimension 326 12 231 5 98 5mm Mounting Dimension 208 219 5mm Mounting Hole Size 5 5mm Net Weight 4 6kg Test condition Rated Input Voltag...

Страница 23: ...20 Any changes without prior notice Version number V2 1...

Страница 24: ...HUIZHOU EPEVER TECHNOLOGY CO LTD Beijing Tel 86 10 82894896 82894112 Huizhou Tel 86 752 3889706 E mail info epsolarpv com Website www epsolarpv com www epever com...

Отзывы: