11
6. Protection
Protection
and recover
Condition
Phenomenon
Parameter
IPower-1* IPower-2* IPower-4*
Overvoltage
protection
and recover
Input Voltage
Ui
Ui>16V
Ui>32V
Ui>64V
Output is OFF
Green indicator fast
flashing
Buzzer sounds
Ui≤14.5V
Ui≤29V
Ui≤58V
Green indicator on
solid
The output is on
Low voltage
protection
and recover
Input Voltage
Ui
Ui<10.8V
Ui<21.6V Ui<43.2V
Output is OFF
Green indicator slowly
flashing
Buzzer sounds
Ui≥12.5V
Ui≥25V
Ui≥50V
Green indicator on
solid
The output is on
Over tem.
protection
and recover
Tem. (T)
Heat sink T
>
80
℃
(IP1000 T
>
75
℃
)
or Internal T
>
60
℃
Inverter turns OFF
Heat sink T≤70
℃
(IP1000
T
≤
65
℃
)
and Internal T≤50
℃
Inverter turns ON
Overload
protection
and recover
S:
Output
power
P
e
: