shutdown in both modes. The setting procedure is
the same with the “output voltage”.
▼Set Interface —Series Rate
The SBR can be set in this page without
shutdown in both modes. The setting procedure is
the same with the “output voltage”. Press
↑ or ↓
button to change the value.
▼Set Interface —Restore Factory settings
Restore factory settings. The setting procedure is
the same with the “output voltage”. Press
↑ or ↓
button to change the value. The device will be
shut down when saving the setting value.
Table 5-2 The parameters in power mode
Item
Code
MIN
Default
MAX
Unit
Remark
Output voltage
V.OUT
40.0
48.0
60.0
V
Output current
C.OUT
0.0
20.5
20.5
A
Real-time output
power
P.OUT
W
Fixed
Real-time input
voltage
V.IN
V
Fixed
Real-time date
DT
Y.M.D
Real-time time
TM
H.M.S
Device address
ID
0
2
180
Serial port baud
rate
SBR
9600
115200
115200
B
Press
↑ or ↓ button to
change the value.
Restore factory
settings
RSET
NO
YES
Press
↑ or ↓ button to
change the value.
Failure interface Fault codes in power mode
:
IOVP, ILVP, IOCP, OOVP,
OLVP, OSCP, DOTP, BOVP, ONLP, CFAL
The largest figure
represents the latest
failure.
The letters represent
the failure code.
SBR 1152
RSET YES
-17-