15.3

 

Functions of Epec Mobile PC buttons 

15.3.1

 

ON/OFF Button 

The 

ON/OFF-

button

 

starts the Epec Mobile PC system in the normal working and 

operating mode and alternatively switches off the system in a controlled manner. The 
controlled switch-off can take place only when the operating system has started. Save 

all work before switching the system off. 

 

Note! Turn the hardware off before switching the main power off. 

 

1. Start on the system  

  

 

Hold the button down for at least half a second (0.5s) 

 

2. Controlled shutdown 

  

 

Hold the button down for about three seconds (3s). 

 

15.3.2

 

Backlight control buttons 

Backlight control buttons

 

are used to control the brightness of the display. The 

backlight is bright and active by default. The user settings are automatically saved for 

the next time that the system is used. 

 

1. Decreasing the backlight brightness 

  

 

Press the left-hand arrow button 

 

2. Increasing the backlight brightness 

  

 

Press the right-hand arrow button 

 

3. Switching the backlight off 

  

 

Press both keys at the same time 

 

4. Activating backlight 

  

 

Press both keys at the same time 

  
 

 

  
 

 

Содержание EPC-M18

Страница 1: ......

Страница 2: ...MAN000239 Epec Oy reserves all rights for modifications without prior notice Epec Mobile PC User manual 2 48 26 06 2008 DOCUMENT VERSIONS Date Description 26 06 2008 Version 1 0...

Страница 3: ...TIONS 12 6 1 Epec Mobile PC 12 6 2 Epec Mobile PC s display 13 7 DEVICE STRUCTURE AND DIMENSIONS 14 7 1 Epec Mobile PC 14 7 2 Epec Mobile PC s display 15 7 3 Structure and accessories 16 8 CONNECTIONS...

Страница 4: ...ng GPS module and GPRS modem telecommunications 42 15 EXTERNAL FUNCTIONS OF THE DEVICE 43 15 1 Epec Mobile PC Buttons and indicator LED s 43 15 2 Functions of the indicator LED s 44 15 2 1 Power LED 4...

Страница 5: ...ion of new features or hardware changes Version changes are indicated on page 2 of the most recent version Epec Oy is constantly developing its product and reserves the right to technical changes with...

Страница 6: ...nd and voltage supply must be disconnected NOTE It is also recommended that the PC be removed from the installation rack for the duration of the work If this is not done the work may damage the hardwa...

Страница 7: ...lure of the hardware Warning The device may only be serviced installed or opened by an authorised service technician Note The product is sensitive to static electricity The device may only be opened a...

Страница 8: ...ems communicating with machines We believe that we know control systems for challenging conditions and we are able to offer a total solution from control units to project services and designing Epec i...

Страница 9: ...9 Epec Oy reserves all rights for modifications without prior notice Epec Mobile PC User manual 9 48 26 06 2008 3 WARRANTY CONDITIONS The product is subject to Epec Oy s general sales and warranty con...

Страница 10: ...r which can easily be connected to the system Groundbreaking structural solutions technical support and quality of the overall system ensure the operability of the unit with regard to water dust and e...

Страница 11: ...an be found at the bottom of the device 1 Model 2 Software version 3 Bios version 4 Date 5 Serial number 6 Quality designation 7 Certificates 8 Operating system licence label 5 1 1 Epec Mobile PC s CP...

Страница 12: ...s e g wake up Connections 4 x COM 2 x full 4 x USB 2 x PS 2 1 x Ethernet 10 100 2 x ISO High Speed CAN 1 x GPS 1 x GPRS Option 1 x LVDS display connection 1 x VGA display connection Option Power suppl...

Страница 13: ...uttons Supply voltage 12 24 VDC Supply voltage range 10 30 VDC Connections Power supply DVI I USB Loudspeaker 1W mono 8 Front panel Brightness control buttons ON OFF button Power ON indicator LED Alar...

Страница 14: ...serves all rights for modifications without prior notice Epec Mobile PC User manual 14 48 26 06 2008 7 DEVICE STRUCTURE AND DIMENSIONS 7 1 Epec Mobile PC 7 1 1 Epec Mobile PC s structure and dimension...

Страница 15: ...MAN000239 Epec Oy reserves all rights for modifications without prior notice Epec Mobile PC User manual 15 48 26 06 2008 7 2 Epec Mobile PC s display 7 2 1 Epec Mobile PC s display 60mm 310mm 240mm...

Страница 16: ...000239 Epec Oy reserves all rights for modifications without prior notice Epec Mobile PC User manual 16 48 26 06 2008 7 3 Structure and accessories 7 3 1 Structure of display and central processing un...

Страница 17: ...08 8 CONNECTIONS 8 1 Epec Mobile PC CPU 8 1 1 Card slots and connectors of Epec Mobile PC s CPU Legend of numbers 1 SIM card slot push push lock 2 Compact Flash card slot 3 Connector for signal and an...

Страница 18: ...c Mobile PC s CPU connector unit mounting plate 8 2 1 Connectors of Epec Mobile PC s CPU Legend of numbers 1 Grounding slip between the casing and connector unit 2 Connector for signal and antenna con...

Страница 19: ...e PS 2 mouse 6pin Mini DIN 5 Disp Data Display data connector DVI D 6 COM1 Serial port 1 9pin D sub male 7 COM3 Serial port 3 9pin D sub male 8 COM2 COM4 Serial port 2 and 4 15pin D sub male 9 USB 1 4...

Страница 20: ...120R 5 Reserved Pin 4 5 connected to ground plane through resistor 120R 6 RxD 7 Reserved Pin 7 8 connected to ground plane through resistor 120R 8 Reserved Pin 7 8 connected to ground plane through r...

Страница 21: ...NC 9 LVDS2 10 LVDS2 11 GND 12 LVDSCLK 13 LVDSCLK 14 5V 15 GND 16 DIGON 17 LVDS0 18 LVDS0 19 GND 20 LVDS1 21 LVDS1 22 GND 23 GND 24 GND C1 VGA RED C2 VGA GREEN C3 VGA BLUE C4 VGA HSYNC C5 GND 6 COM 1 S...

Страница 22: ...S output 10 13 6V max 200 mA 11 12V UPS output 10 13 6V max 200 mA 12 Reserved Do not connect 13 COM2 RxD 14 Reserved Do not connect 15 GND 8 COM2 COM4 Serial port 2 and 4 15pin D sub male 9 USB Ports...

Страница 23: ...LAY POWER 15 DISPLAY POWER 13 CAMERA 2 camera inputs 5 pin D Sub female PIN Signal 1 Reserved Do not connect 2 Reserved Do not connect 3 Reserved Do not connect 4 GND 5 GND 6 GND 7 GND 8 GND 9 GND 10...

Страница 24: ...igital input to Webasto controlled pre heating Reserved if pins 1 and 2 are in use necessary in connection with pre heating in this case pin A2 must be connected 4 CHGND input Grounding if the externa...

Страница 25: ...nnectors are located under the mounting plate at the back of the display 1 2 3 4 5 Connector number Item designation Connection 1 Disp Power Display power supply 15pin D Sub male 2 USB Hub USB Hub con...

Страница 26: ...LVDS2 11 GND 12 LVDSCLK 13 LVDSCLK 14 5V 15 GND 16 DIGON 17 LVDS0 18 LVDS0 19 GND 20 LVDS1 21 LVDS1 22 GND 23 24 C1 C2 C3 C4 C5 GND 2 DISP PWR Display power supply connector 15pin D Sub male PIN Signa...

Страница 27: ...tions without prior notice Epec Mobile PC User manual 27 48 26 06 2008 3 USB Port USB hub connector USB B PIN Signal 1 VBUS 2 D 3 D 4 GND 4 USB ports 5 6 2 USB A PIN Signal 1 VBUS 2 D 3 D 4 GND 5 USB...

Страница 28: ...ile PC can be mounted on the machine either as a robust surface installation or as a rack installation by means of a separate mounting plate in which case it can be fastened and released using quick r...

Страница 29: ...ith the mounting plate We recommend four M6x12 threaded screws The device is fastened from beneath the mounting plate or connector unit Mounting screws from the side 9 1 1 Location of the mounting scr...

Страница 30: ...processing unit lies on top of the connector unit Second phase Push the central processing unit as far as it goes Third phase Lock the central processing unit with the key and place the key in the pla...

Страница 31: ...Mobile PC User manual 31 48 26 06 2008 9 2 Mounting accessories for a model installed without the mounting plate Epec recommends four M5x12 threaded screws Mounting takes place at four points in the c...

Страница 32: ...Epec Mobile PC User manual 32 48 26 06 2008 Vertical installation NOTE If you mount the central processing unit in a vertical position with the connectors pointing upwards make sure that the connecto...

Страница 33: ...The fans are only used if the temperature inside the central processing unit exceeds 30 degrees or in the pre heating mode This extends the lifetime of the fans It must be ensured at the mounting site...

Страница 34: ...even though the fuel heater is on In that case only the fans are used The CPU fans are used in all heating modes when the outdoor temperate is over 10 C This temperature is also the limit value for s...

Страница 35: ...t start until its inside temperature is high enough The maximum heating time is 30 minutes after which the hardware will start The same heaters and temperature values are used in the normal heating mo...

Страница 36: ...Epec Oy reserves all rights for modifications without prior notice Epec Mobile PC User manual 36 48 26 06 2008 12 BLOCK DIAGRAMS 12 1 Central processing unit 12 1 1 Block diagram for the central proce...

Страница 37: ...MAN000239 Epec Oy reserves all rights for modifications without prior notice Epec Mobile PC User manual 37 48 26 06 2008 12 2 Display 12 2 1 Block diagram for the display...

Страница 38: ...or Epec Mobile PC In customer specific installations please contact Epec Oy s product support techsupport epec fi Example 1 The pre heat system controls the pre heating 24V when the main switch is in...

Страница 39: ...r manual 39 48 26 06 2008 Example 3 There is a constant electricity supply to the system 12V Pre heating is connected on through a digital input 13 3 1 Switching example 3 Example 4 There is a constan...

Страница 40: ...ehicle s ignition key is in the OFF position The reading must be 12V 12V system or 24V 24V system 3 Pre heating The power supply is measured in the multimeter s voltage range The reading must be 12V 1...

Страница 41: ...uad band GSM GPRS modem as an accessory Test the phone by means of the software that you normally use in your work To test serial interface you can use the execute modem inquiry key found in the telep...

Страница 42: ...the tests using the Windows Hyper Terminal program The GPS module is internally connected to COM4 and the GPRS phone to COM1 Input data Open the Windows Hyper Terminal application Type GPS4 Click OK T...

Страница 43: ...LED s The button labels for the central processing unit and display are shown in the pictures The label for the central processing unit has four LED s and one ON OFF button The label for the display h...

Страница 44: ...nds 2 The system is not yet warm enough to start up The LED is blinking and is off for a short period of time and the ON OFF button of the central processing unit or display has been pressed in the 24...

Страница 45: ...even if the ambient temperature is relatively high Heater modes 1 Heater of the central processing unit and display is in operation The LED of the central processing unit is on The LED of the display...

Страница 46: ...ain Voltage Low Error Code 3 Overvoltage in the 12V UPS electricity supply UPS Voltage High Error Code 4 Low voltage in the 12V UPS electricity supply Main Voltage Low Error Code 5 Central processing...

Страница 47: ...are off before switching the main power off 1 Start on the system Hold the button down for at least half a second 0 5s 2 Controlled shutdown Hold the button down for about three seconds 3s 15 3 2 Back...

Страница 48: ...l 48 48 26 06 2008 16 FURTHER INFORMATION Name of document Document location C programming Contact technical support Diagnostics Contact technical support service CAN configuration Contact technical s...