5 Parking the stacker securely

When you leave the stacker it must be securely parked even if you only intend to leave
it for a short time.
Do not park the stacker on a slope. The load forks must always be lowered to the ground.
– Lower the load forks.
– Set the key switch (3) to “0” and remove the key.

6 Display instrument

The LEDs (1) represent battery residual capacity, The LCD (2) displays the operating hours

6.1 Battery Discharge Indicator

When the stacker has been released via the key switch, the battery charge status is
displayed.
The colours of the LEDs (1) represent the following conditions:

LED colour

value

Green

Standard battery residual capacity

70-100%

Orange

Standard battery residual capacity

3060%

Flashing Red

Standard battery residual capacity

0-20%

Battery Discharge for 70%, A flashing red show on storage battery charge warning.
Battery Discharge for 80%, Two flashing reds show on battery charge used up warning, Lifting
is now inhibited. The battery must be charged.

6.2 Operating hours display

Display range between 0.0 and 99,999.0 hours. Travel and lifting are logged. This is a backlit
display.

Содержание ES10-10WA

Страница 1: ...1...

Страница 2: ...1...

Страница 3: ...so maybe there are some differences between your product and the description in this manual And the operator manual details will be different because of customer s special requirements If you have an...

Страница 4: ...15 4 3 Collecting and depositing loads 17 5 Parking the stacker securely 18 6 Display instrument 18 6 1 Battery Discharge Indicator 18 6 2 Operating hours display 18 6 3 Power up test 19 7 Troublesho...

Страница 5: ...ze filter Replacing the gauze filter 32 6 8 Checking electrical fuses 33 6 9 Recommissioning 34 7 Decommissioning the industrial stacker 34 7 1 Prior to decommissioning 34 7 2 During decommissioning 3...

Страница 6: ...industrial stacker himself or on whose behalf it is used In special cases e g leasing or renting the proprietor is considered the person who in accordance with existing contractual agreements between...

Страница 7: ...with a steered drive wheel It is designed for use on level floors to lift and transport palletised goods Open bottom pallets or roll cages can be lifted The capacity can be obtained from the data plat...

Страница 8: ...ies Item Component Item Component 1 Caster wheel 7 Key switch 2 Drive wheel 8 Battery display instrument 3 Tiller and tiller arm 9 Battery panel 4 Controller 10 Front panel 5 Mast 11 Lift mechanism 6...

Страница 9: ...3 0 16 0 11 0 16 m s Lowering speed laden unladen 0 19 0 18 0 22 0 13 0 32 0 23 high speed m s 0 16 0 12 low speed Maximum gradeability laden unladen S2 5 min 8 16 6 12 3 2 Dimensions Description ES10...

Страница 10: ...0 3300 3700 2270 100 3530 3600 4000 2420 100 3830 3900 4300 2550 100 4090 4200 4560 Two Stage Mast Free Lifting 1819 1320 2620 2700 3119 1969 1470 2920 3000 3419 2119 1620 3220 3300 3719 Three Stage M...

Страница 11: ...765 2320 100 3550 3600 4065 Three Stage Mast Free Lifting 1830 1390 3990 4000 4470 2022 1590 4490 4500 4970 ES20 WA Standard Mast Types mm Mast types Close Mast height Free height lift height Extended...

Страница 12: ...7...

Страница 13: ...rating at 5 C to 40 C Special equipment and authorisation is required if the stacker is to operate constantly below 5 C or in a cold store or in extreme temperatures or conditions of fluctuating air h...

Страница 14: ...9 Item Description 1 Waring decal 2 Refer to manual decal 3 Truck data plate...

Страница 15: ...Max capacity 3 Model type 11 Max lift height 4 Serial NO 12 Rated capacity 5 Manufacture date 13 Load center For queries regarding the truck or ordering spare parts please quote the truck serial numb...

Страница 16: ...nnel Damage and Faults The supervisor must be immediately informed of any damage or faults to the stacker stackers not safe for operation e g wheel or brake problems must not be used until they have b...

Страница 17: ...us 3 Switch switch Switches control current on and off Removing the key prevents the stacker from being switched on by unauthorised personnel 4 Tiller Is used to steer the stacker 5 Controller Control...

Страница 18: ...13...

Страница 19: ...Only use lanes and routes specifically designated for stacker traffic Unauthorised persons must stay away from work areas Loads must only be stored in places specially designated for this purpose Dri...

Страница 20: ...must enter lifts with the load in front and must take up a position which does not allow it to come into contact with the walls of the lift shaft Persons riding in the lift with the stacker must only...

Страница 21: ...s the travel switch 5 in the desired direction fwd or rev The more the tiller rotates the speed is faster Driving in high speed Set the tiller 4 to the travel range k and press the travel switch 5 in...

Страница 22: ...ing the stacker from rolling downhill With the travel switch set to zero the brake is automatically applied after a short jerk the controller detects the stacker is rolling back on the slope The servi...

Страница 23: ...er has been released via the key switch the battery charge status is displayed The colours of the LEDs 1 represent the following conditions LED colour value Green Standard battery residual capacity 70...

Страница 24: ...Check battery charge charge battery if Necessary Test fuses Interrupt charging Load can not be lifted Charge capacity below 20 40 Hydraulic oil level too low Excessive load Charging the battery Check...

Страница 25: ...e covered with a non slip insulation mat Battery Disposal Batteries may only be disposed of in accordance with national environmental protection regulations or disposal laws The manufacturer s disposa...

Страница 26: ...ly ventilated room When charging the tops of the battery cells must be exposed to provide sufficient ventilation Do not place any metal objects on the battery Before charging check all cables and plug...

Страница 27: ...s not compressed The hooks must be attached to the eyes 4 of the battery in such a way that they cannot fall onto the battery cells when the lifting gear is discharged Attach the lifting gear to the a...

Страница 28: ...e reverse order of operations After installing the battery again check all cables and plug connections for visible signs of damage Before starting the stacker the battery panel must be firmly closed C...

Страница 29: ...ervice department has field technicians specially trained for these tasks We therefore recommend a maintenance contract with the manufacturer s local service centre Lifting and jacking up When an indu...

Страница 30: ...More demanding conditions dust temperature require more regular lubrication The prescribed chain spray must be used in accordance with the instructions Applying grease externally will not provide suf...

Страница 31: ...y acid level and battery voltage Travel 4 1 Check motor suspension 4 2 Check the transmission for noise and leakage 4 3 Replace gear oil if service life exceeded 10 000 hours 4 4 Check travel mechanis...

Страница 32: ...6 7 Replace hydraulic oil filter 6 8 Replace hydraulic oil 6 9 Check wheels for wear and damage Agreed performance levels 7 1 Lubricate stacker in accordance with Lubrication Schedule 7 2 Test run 7...

Страница 33: ...28 5 Lubrication Schedule Contact surfaces Hydraulic oil filler neck Transmission oil filler neck Transmission oil drain plug...

Страница 34: ...with hot components or naked flames Only use clean containers when filling up with consumables Do not mix consumables of different grades The only exception to this is when mixing is expressly stipul...

Страница 35: ...event the stacker from accidentally starting When working under a raised lift stacker secure it to prevent it from tipping or sliding away 6 2 Removing the front panel Open the battery panel Remove th...

Страница 36: ...pends on the lift height The oil level must be checked when the load forks are lowered If necessary add hydraulic oil of the correct grade see Section 5 Installation is the reverse order 6 6 Check tra...

Страница 37: ...the gauze filter Prepare the stacker for maintenance and repairs see Section 6 1 Remove the front panel see Section 6 2 Undo the union 5 Remove connection and take out the gauze filter Insert a clean...

Страница 38: ...the stacker for maintenance and repairs see Section 6 1 Dismantle the front panel see Section 6 3 Check rating of all fuses in accordance with table replace if necessary Item To protect Rating 6 Tract...

Страница 39: ...d If the stacker is to be out of service for more than 6 months further measures must be taken in consultation with the manufacturer s service department 7 1 Prior to decommissioning Thoroughly clean...

Страница 40: ...ecial safety department with trained personnel to carry out such checks The stacker must be inspected at least annually refer to national regulations or after any unusual event by a qualified inspecto...

Страница 41: ...decommissioning or disposal of the stacker must be performed in accordance with the regulations of the country of application In particular regulations governing the disposal of batteries fuels and e...

Отзывы: