If assembled incorrectly, the system will present a
fire hazard. Please read this installation guide
thoroughly. It is especially important to consider
applicable dimensions and observe the following
instructions:
l
The sauna heating unit is intended only for a supply
voltage of 400 V AC 3N.
l
The installation and connection of the sauna heating
unit, control unit and other electrical equipment must
be accomplished only by an expert. In this regard it
is especially important to meet the required safety
precautions in accordance with VDE 0100 v. §49 DA/
6 and VDE 0100 part 703/11.92 §4.
l
The sauna heating and control units may be installed
only in sauna cabins made of suitable, low resin and
untreated material (for example: Nordic pine)
l
The minimum height of the sauna cabin must be
1.90m on the inside.
l
There should always be a provision for air intake and
exhaust vents in every sauna cabin. The air intake
vents must always be aligned behind the sauna
heating unit, ca. 5 to 10 cm above the floor. Please
use the minimum dimensions of the air intake and
exhaust vents listed inTable 1.
l
Only a sauna oven with the appropriate heating
capacity may be installed in the sauna cabin (see
Table 2).
l
The exhaust vents must always be placed towards
the sauna heating unit diagonally in the rear sauna
wall, lower area. The air intake and exhaust vents
must not be closed. Please observe the information
provided by your sauna cabin supplier.
l
For the adjustment and control of the sauna heating
unit, one of the control units mentioned later must be
used. This control unit must be attached to a suitable
location on the outer wall of the cabin, the associated
sensor housings in the interior of the sauna cabin in
accordance with the installation guide which
accompanies the control units.
l
The cabin lighting with corresponding mounting must
be of a type that it is splash-proof and able to withstand
a surrounding temperature of 140° C. Therefore,
only a VDE-certified sauna lamp of 40 W maximum
may be installed for use with the sauna oven.
l
The sauna system (sauna heating unit, control unit
and lighting etc.) may be hard-wired to the power
source only by a locally certified electrician. All
connecting lines laid on the inside of the cabin must
be able to withstand a surrounding temperature of at
least 140°C. For practical purposes, a silicone line
should be used. If single-wired cables are used as
connecting lines, they must be protected by flexible
metal tubing. The minimum diameter of the connecting
line and the suitable cabin size in proportion to the
power supply capacity are listed in Table 2.
l
During the installation of the sauna heating unit,
make certain that the vertical clearance between the
upper edge of the sauna heating unit and the sauna
ceiling is at least 90 cm. The horizontal (lateral)
clearance between the sauna heating unit and the
cabin wall is at least 6 cm (illust. 1). Fundamentally,
it is important to make sure that the sauna heating
unit is not placed on a floor that consists of an easily
flammable material (wood, synthetic flooring or
similar material). Ceramic tiles or similar materials
are practical in the area of the sauna.
l
The distance between the oven safety grid or recliner
bench and other flammable materials and the sauna
heating unit is at least 4 cm. The safety grid height
must be approximately equal to the frontal height of
the sauna heating unit.
Minimum clearances
Cabin wall
Oven safety grid
4 cm
4
cm
50
cm
4 cm
Illust. 1
50 cm
6,7
35 x 4 cm *
9,0
35 x 6 cm *
12,0
35 x 7 cm *
Power supply
capacity in KW
* oder nach Angabe des Kabinenherstellers
Table 1
Minimum dimensions of the air
intake and exhaust vents in cm
Table 2
Power
supply
capacity
in kW
suitable for
cabin size
in m³
Minimum diameters in mm² (copper wire)
connection to 380-400 V AC 3N
Oven connecting
line,
control unit to
oven
Power supply
lead wire, power
supply to
control unit
Fuse
protection
in A
6,7
ca. 6 - 10
5 x 2,5 mm
2
5 x 1,5
mm
2
3 x 16
9,0
ca. 10 - 14
5 x 2,5 mm
2
5 x 1,5
mm
2
3 x 16
12,0
ca. 14 - 18
5 x 4 mm
2
2 x 5 x 1,5
mm
2
3 x 20
For use with control units 4535 F,
EMOTEC H 9003, EMOTEC D 9000
(without vaporizer) or according to
the instructions of the sauna cabin
manufacturer.