Installation guide for power control unit EMOTEC L09 Relay
The power control unit is delivered equipped for a voltage of 380 - 400 V AC 3N with a
maximum breaking capacity of 16 A per phase and with a safety shutdown in connection with
our sauna control unit as standard.
Installation and connection of the sauna systems and other electrical equipment may
be undertaken only by an expert; please note that this is subject to VDE 0100, Part
703/2006-02.
Sauna systems may be connected to the power supply only by hard wire.
Wall mounting
Mount the control unit outside the sauna
cabin only. The most practical mounting
point would be the wall area onto which
the sauna heater is mounted on the inside,
except on the outside of the cabin. If elec-
trical conduits are present, mount the control
unit accordingly. To mount the control unit,
please follow these instructions:
lllust. 1
1. Remove the cover of the control unit.
To do this press the fastening tab in-
wards with a fl at screwdriver and remove
the housing top by pivoting it upwards
(Illust.1).
Drill the threaded holes for the included
4 x 20 mm wood screws according to Il-
lust. 3 & 3.1.
2. Insert one of the wood screws into the
upper middle hole. This screw will be the
mounting point for the control unit. Make
sure the screw is projecting out from wall
about 3 mm. (Illust. 3.2)
3. Hang the control unit onto the 3 mm pro-
jecting screw.
Insert the included rubber sleeves into
the openings on the back side of the hou-
sing and lead the electrical cable through
these openings.
Screw the lower part of the housing onto
the cabin wall using the lower threaded
holes. (Illust. 4)