background image

3

GB

1

.3 General safety precautions

l

This device has not been designed for

being used by persons (including
children) that are physically or mentally
handicapped or have sensory
disabilities. Moreover, it is not allowed to
use this device without sufficient
experience and/or knowledge, unless
these persons will be supervised by
persons responsible for their security or
in case they have been instructed how to
use this device.

l

Children are to be supervised in order

to make sure that they do not play with
this device.

l

Attention:

 It is forbidden to install the

control box in a closed switch cabinet or

behind a wooden panelling!

l

The electrical installation may be done

only by a qualified electrical technician.

l

You must comply with the regulations of

your electrical supplier and applicable
VDE regulations (DIN VDE 0100).

l

WARNING:  Never attempt repairs
or installations yourself, as this

could result in serious injury.  Only a
qualified technician may remove the
housing cover.

l

Please note the dimensions in the

assembly instructions, especially when
installing the temperature sensor.  The
temperature above the oven is critical for
the temperature setting. The temperature
can be held within operating parameters
and a minimal temperature gradient
inside the sauna cabin can be achieved
only if unit is assembled correctly.

l

The device may only be used as intended

as a control unit for sauna ovens up to 9
kW. (Up to 36 kW when combined with a
breaking capacitor).

l

Completely disconnect the control unit

from the electrical circuit, i.e. flip all circuit
breakers or the main circuit breaker
during installation or repair.

l

Please note the safety and installation

information from the sauna oven
manufacturer.

2 Assembly of the control unit

2.1 Wall mounting

Mount  the control unit outside the sauna
cabin only.  The most practical mounting
point would be the wall area onto which
the sauna oven is mounted on the inside,
except on the outside of the cabin. If
electrical conduits are present, mount the
control unit accordingly.  To mount the
control unit, please follow these
instructions:

Illust. 1

Fastening screws

1. Remove the cover of the control unit.

Loosen the fastening screws below the
control panel.  If your unit uses control
knobs, remove them.  Enlarge the holes
for the electrical cables (Illust. 4) with a
sharp knife.  Drill the threaded holes for
the included 4 x 20 mm wood screws
according to Illust.s 3 & 3.1.

2. Insert one of the wood screws into the

upper middle hole.  This screw will be
the mounting point for the control unit.
Make sure the screw is projecting out
about 3 mm.  (Illust. 3.2)

3. Hang the control unit onto the 3 mm

projecting screw.  Lead the electrical
cable through the holes you enlarged in
step 1 and screw the lower part of the
housing onto the cabin wall using the
lower threaded holes.  (Illust. 4)

Содержание ECON A1

Страница 1: ...1 GB 29343277en 43 06 Installation and user s manual ECON A1 GB IP x4...

Страница 2: ...C Storage temperatures 20 C bis 70 C 1 2 Package contents subject to change Included with the control unit are 1 an oven sensor board with overheat shutoff protection KTY sensors with sensor housing t...

Страница 3: ...assembled correctly l The device may only be used as intended as a control unit for sauna ovens up to 9 kW Up to 36 kW when combined with a breaking capacitor l Completely disconnect the control unit...

Страница 4: ...tween the wood boards Therefore you have to mount the control unit farther away from the cabin wall so you can lead the cables into the unit In this case use the included spacer tubes as shown in Illu...

Страница 5: ...vaporizer according to the instructions provided by the manufacturer in front of the air intake opening Lead the silicon lines and electrical conduits to their respective terminals on the control unit...

Страница 6: ...x 2m according to Illust 7 and 8 in larger cabins according to Illust s 7 and 9 35 cm 19 cm 20 Illust housing red red sensor board hole sensor housing sauna ceiling center sensor housing on middle sec...

Страница 7: ...to familiarise you with the operations and features of your sauna control system In each case the illustrations next to the text show the displays visible on the control unit The symbol means that the...

Страница 8: ...displayed At expiration of the heating time delimitation the plant switches off automatically If you want to switch the plant off manually press the button When switching off the control reacts mode...

Страница 9: ...as a value for the temperature around the sauna benches Depending on oven capacity and placement of the fresh air vents undesirable influences can alter these measurements not allowing the maximum tem...

Страница 10: ...f press on the left part of the rocker to the second position switch position II In order to put the unit back into operation switch back to the starting position switch position I Control unit switch...

Страница 11: ...ctrical connection of the sauna heater and the control box has to be carried out through the specialist of an authorized electric shop We would like to mention to the fact that in case of a warrenty c...

Страница 12: ...ex pressive description of the fault This warrenty covers damaged parts but no defects due to wear and tear In case of complaint please return the equipment in its original packaging or other suitabl...

Отзывы: