Electrical installation
5.2 Connections
The relay box is connected with a live current of 400 V 3 N AC 50 Hz and
fused separately with 3 x 16 A. A 16 A cut-out with at least K characteristic
must be used for fuse protection.
As a rule, only a fixed connection may be connected to the mains supply,
whereby a configuration is provided that makes it possible to separate the
system from the mains supply with a contact opening width of at least
3 mm (all poles).
5.2.1 Sensors
The temperature/humidity in the sauna cabin is set via the control panel.
The set values are checked by sensors and controlled by the relay box.
The sensors are connected to the RJ10 sensor jacks using RJ10 plugs. Each
sensor can be connected to any one of the three jacks. The connected sen-
sors are automatically detected by the control unit.
Humidity sensor
The (optional) humidity sensor regulates the relative air humidity in %. At
the same time, the control unit attempts to keep the set humidity as pre-
cisely as possible.
The humidity sensor regulates the humidity according to the following
indicated characteristic curve:
All values that lie below or on the characteristic curve can be set and
used.
When setting a parameter, e.g. temperature, the setting for the other
parameter (humidity) is automatically adjusted.
Values that lie above the characteristic curve cannot be set.
Characteristic curve for temperature/humidity according to EN 60335-2-53
T
[°C]
rH
[%]
80
70
60
50
40
100
90
80
70
60
50
40
30
20