INSTALLATION - ROUGH IN
Determine Location of Shower
Wall depth: min 70mm – max 85mm from finished wall surface to the back of box.
This shower cannot be installed sideways, or upside down. The mixer body must be installed in the
correct direction, with the 2 inlets on the horizontal plane. This will ensure the handle points in the
correct orientation and to align with the “H” and “C” markings on the front panel.
In-Wall Body Component
1.
Ensure plumbing lines are flushed prior to installation, as debris in cartridge will void
warranty.
2.
Remove temperature adjustment lever handle and front panel from Shower Box, taking care
not to damage any cable while doing so. Disconnect spade connectors from solenoid if they
are connected.
3.
Secure the Shower Box to the internal cavity within the wall. The Shower Box can be fixed to
a masonry wall or wall frame using screws suitable for the fixing method. (Fixing screws not
supplied.)
When mounting the Shower Box, take note of the minimum and maximum wall thickness
and the dimensions shown so that the nogging or recess is correctly positioned and takes
into account the thickness of the finished wall.
To increase the wall depth adjustability, unscrew the four Wall Depth Adjustment Nuts,
bring the position of Body Fixing Plate forward, and secure the Body Fixing Plate in place
again with four nuts located behind the plate.