LOCKING THE SPOUT IN A FIXED POSITION
The ATM607, ATM610X and ATM611 models come
assembled with the Spout in a Swivel orientation where it
can be rotated 120 degrees over the basin.
To fix the spout in the straight position:
1. Rotate the spout so it is positioned straight out over
the basin.
IMAGE 41
and
42
2. Tighten the M5 grub screw located on the back of
the Swivel spout so it can engage within the locator
groove on body. Wind in the grub screw until it comes
to a light stop and the head of the grub screw is close
to being flush with the surface of the swivel spout.
IMAGE 43
Note: the spout might be required to be rotated a
little while winding in the grub screw to find the
correct central location groove.
CAREFUL: Do not over tighten grub screw as it can
cause the spout to leak.
3. Use the 1.5mm Allen key to loosen the 2x M3 grub
screws located on the spout locking nut.
IMAGE 44
4. Using the SQX prong tool tighten the Spout locking
nut to further secure the swivel spout.
IMAGE 45
5. Use the 1.5mm Allen key to again tighten both M3
grub screws and test the spout is centrally located
and secure.
IMAGE 46
6. Test operation and check for leaks. If leaks occur
around the spout, loosen off M5 grub screw slightly.