REPLACING THE SENSOR
STEP 1
Disconnect the sensor from the solenoid and power source.
To remove the sensor, simply place an even pressure on the
2 lenses and firmly press out of its tolerance fit location.
SEE
IMAGE 40
STEP 2
Connect the new sensor to the cables, making sure the lines on
the two connectors align.
For 12V mains powered versions, the transformer lead MUST
connect to the cable marked “12V’, leaving the other cable to the
solenoid. SEE IMAGE 18 page 13
For battery versions, ensure the white line on the sensor cable
connector aligns with the moulded line of the battery casing.
Warning: Cross connection here will damage the sensor and
void the product warranty
The sensor must be oriented so that the text on the back is
facing upright. SEE IMAGE 49
IMAGE 49
SERVICING THE SENSOR
Enware Product Code:
ENMS236
- Active Sense 6V Battery Op Sensor
ENMS237
- Wave On/Off 6V Battery Op Sensor
ENMS238
- Active Sense 12V Mains Power Sensor
ENMS239
- Wave On/Off 12V Mains Power Sensor
To service the Sensor, first close the valve and remove the faceplate, spout and dress flange. The sensor
can be serviced while still assembled in the face plate bracket or when the bracket is removed from the
mixer assembly.
CLEANING
Enware Product should be cleaned with a soft damp cloth using only mild liquid detergent or soap and
water. Do not use cleaning agents containing a corrosive acid, scouring agent or solvent chemicals. Do not
use cream cleaners, as they are abrasive. Use of unsuitable cleaning agents may damage the surface. Any
damage caused in this way will not be covered by warranty.
If re-greasing spindles or seals, always use a silicon based potable water approved lubricant such as
Hydroseal Food Pro.
IMAGE 48
SERVICE AND MAINTENANCE