Prior to servicing the strainers, turn off both the hot and cold water supply via
the Isolation valve within the inlet connectors. SEE IMAGE 27.
STEP 1
Using a 3/8” Allen key unscrew the the SQX check valve/
strainer assembly and remove from the mixer.
SEE IMAGES 28 & 29
STEP 2
The check valve/strainer assembly should be cleaned with a
dilute water solution of suitable descaling solvent (such as CLR),
checked for physical damage and then thoroughly rinsed with
clean water. SEE IMAGE 30
STEP 3
Ensure there is no debris caught within the sealing faces.
When service is complete, re-fit SQX check valve/strainer assembly and
hand tighten with the Allen key. Test for water tightness.
IMAGE 28
IMAGE 29
IMAGE 30
SERVICING THE STRAINERS AND CHECK VALVES
Enware Product Code:
ATMS693
- Strainer / Check Valve Assembly (1 Pair)