20
Aquablend 2500 Thermostatic Mixing Valve
Call 1300 369 273
www.enware.com
FAULT /
SYMPTOM
CAUSE
RECTIFICATION
Hot water flows
into the cold
water system
or vice versa.
Non-return valves.
Replace non-return
valves (ATMS312).
Valve is noisy.
Water velocity above
velocity requirements
of AS3500.1, 3.4
Reduce water velocity.
Spare Parts
PART
REPLACEMENT
PART No.
Cartridge
As required
ATMS3002
O-Ring Kit - 3 cartridge,
1 spindle, 1 piston
12 monthly
ATMS301
Inlet Fitiing O-ring
As required
ATMS302
Piston Assembly
As required
ATMS303
Locknut & top Cover
As required
ATMS304
Inlet Fitting Strainers
As required
ATMS305
Thermostatic Element
5 yearly
ATMS306
Seat Shell with seat
As required
ATMS308
Lower/Upper
Top Cap Assembly
As required
ATMS309
Mixed Water Temperature
Adjuster
As required
ATMS310
Return Spring
As required
ATMS311
Non-Return Valve
As required
ATMS312
Face Seal
As required
ATMS313
Pressure Test Point Plug with
O-ring (pair)
As required
ATMS238
Pressure Test Point Plug with
washer (each)
As required
ATMS1314