background image

62

 

Chapter 6 Firewall Tab | Bellwin 

 

6-2 MAC Filter 

User can set up permitted Mac address, and repeat the action for 

increasing many sets of Mac address.

 

 

 

 

 

 

 

Enabled MAC Filter:

Mark this square to enable Mac filter and press Save 

button to store the setting after permitted Mac address was built. System will 

reject people who try to access this remote power manager from other Mac 

addresses. Unmark the square and press Save button if you expect to cancel 

this function. 

Allowed

 

MAC  Address: 

Enter  permitted  MAC  number.  Please  click  ADD  to 

implement this action. To delete a specific IP 

address, please clicks “X”. 

※ 

MAC blocking feature is only available for local area network; if a router is 

used, the original adapter MAC address may be changed. 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание NSH-4242

Страница 1: ......

Страница 2: ......

Страница 3: ...likely to cause harmful interference in which case users will be required to correct the interference at their own expense RoHS This product is unto the RoHS standard Safety Recommendations Caution M...

Страница 4: ...o not expose the device in water or humid air 8 You may clean the device only with dry mop 9 Use only attachments or accessories specified by the manufacturer 10 Only appropriately qualified and skill...

Страница 5: ...k PDU to be free from defects in materials and workmanship for a period of one year from the date of purchase We will make our own decision within the warranty time and proof of purchase to remove or...

Страница 6: ...the internet causing the damage or loss to the product and or any defects in materials that repaired by anyone other than an approved agent Please contact with your local distributer information and w...

Страница 7: ...s 2 1 5 Control and Indicators 3 1 6 Package Contents 5 Chapter 2 Hard ware Installation 6 2 1 Product Installation 6 Chapter 3 First Time Setup 7 3 1 IP Setting 7 3 2 Setup Wizard 7 Language 8 Accoun...

Страница 8: ...r 5 System 45 5 1 Network 45 5 2 Email Server 47 5 3 SMS Server 49 5 4 SNMP 52 5 5 SYSLOG 55 5 6 IDCView 56 5 7 Serial Port UART 57 5 8 Peripheral 59 5 9 Other 60 Chapter 6 Firewall Tab 61 6 1 IP Filt...

Страница 9: ...tallation 88 13 1 Windows 88 13 2 Linux Centos 95 Chapter 14 IP Search Utility 101 Appendix 103 HTTP Message API example 104 Message format Explanation 1 106 HTTP API example 107 RJ45 to DB 9 cable 10...

Страница 10: ......

Страница 11: ...reds of SH products at a single interface through IDCView central control software accordingly greatly simplifying the issue of device network IP management 1 2 Applications Monitoring and management...

Страница 12: ...and email alerts for real time detection and alarm of important devices Support to send different messages to different email addresses and message receivers Record the user operation information and...

Страница 13: ...h the product 1 5 Control and Indicators 1 RJ45 Ethernet connected port 6 Serial Port Provide to enable terminal control API control UPS detect 2 USB connected Port 7 2 Dry Contact Output Port LED lig...

Страница 14: ...ing Light Lights remain Abnormal please call for your distributor 9 4 Dry Contact Input LED light up PDU connect normally LED light off PDU connect abnormal 5 Device Operating Indicating Light Slow fl...

Страница 15: ...n 5 1 6 Package Contents Remote Environment Monitor 1 CD Rom with User s Manual 1 Power Cord 1 If any of the above accessories is missed or cannot be used please contact with the location you purchase...

Страница 16: ...make sure the entire power is not working before install in addition please follows the instruction while installing 2 1 Product Installation Please make sure to follow the installation tutorial as f...

Страница 17: ...ired automatically through DHCP server The device IP will be preset as 192 168 1 10 if there is no DHCP server 2 IP Search Utility see Chapter 13 IP Search Utility can help user get the IP address 3 2...

Страница 18: ...uage Currently available in English Traditional Chinese Simplified Chines press Next to continue Account Setting This menu is for setting the admin account and password of the device all the fields sh...

Страница 19: ...Bellwin Chapter 3 First Time Setup 9 Host setting The product is assigned dynamically DHCP To specify a fixed IP address please fill in IP Address Subnet Mask and Gateway...

Страница 20: ...S server provided by ISP providers then you can set up two DNS servers If you do not know your DNS server address please check it from Windows O S by these steps Go to START ALLPROGRAMS ACCESSORIES CO...

Страница 21: ...y HTTP the other is a security measure HTTPS Comment setting rolling down for Http or Https as concern transmissions If you want a security measure instead of HTTP The default is 80 or HTTPS The defau...

Страница 22: ...ze with Time Server Sync with time server When this option enabled device time will synchronize with time server Time Server Please fill in time server IP address or click to select time server option...

Страница 23: ...ter 3 First Time Setup 13 Time zone Please fill in the time zone where the device is The system is based on Greenwich Mean Time thus an accuracy setting to time zone may affect the time record of even...

Страница 24: ...14 Chapter 3 First Time Setup Bellwin Daylight saving time Select daylight saving time Overtime setting This menu is for setting the time of web page overtime operation...

Страница 25: ...Bellwin Chapter 3 First Time Setup 15 Setting completion Press finish and equipment will automatically reboot to update configurations...

Страница 26: ...win 3 3 Login It will show a fixed IP Address after rebooting User can see IP address on IP Search Utility see Chapter 13 IP Search Utility First time login please key in the default account and passw...

Страница 27: ...er login successfully the browser will pop up a main operation window for Smart Monitor managing interface as the following figure 1 User Login Information 2 Reset Timeout 3 Logout 4 Select Tap 5 Oper...

Страница 28: ...atus view and set relevant peripheral parameters 4 1 Monitor Tab Display abnormal or alarming statues of PDU Output Switch Temp Probe RH Probe and Input Detection if the abnormal information is in red...

Страница 29: ...ot higher than High Alarm or lower than Low Alarm setting Monitor Alert Offline Monitor is checked And external temperature is higher than High Alarm or lower than Low Alarm setting Monitor Off line O...

Страница 30: ...otal current Total current of PDU Branch 1 Display the power consumption of branch 1 power current only apply in 30 32A PDU Branch 2 Display the power consumption of branch 2 power current only apply...

Страница 31: ...lue High Alarm Set up the values of high infeed alarm When current is higher than you set the alarm will occur Low Alarm Set up the values of low infeed alarm When current is lower than you set the al...

Страница 32: ...Bellwin 4 3 Outlet Control Show the current output and switch status User can directly control the switch Name Enter the name of connected equipment If user has no right to control the port it will d...

Страница 33: ...icon shows the status of switch You may just click it to open close the switch On off state Displays the current power outlet on off state For operation of power outlet on off click the on off icon w...

Страница 34: ...n To operate many switches at once please do as follow Mart on the checkbox of switches or All that you want to operate Select the action you want ON OFF REBOOT or SHORT ON Click Setup the browser wil...

Страница 35: ...ff Delay first Do as shows REBOOT To reboot the switch please turn off and on the power when switch are power on Reboot time is the same as Power on Delay SHORT ON Short on means to turn on and off th...

Страница 36: ...them with special switch Descriptions as below Select You may select existed groups for deletion and revising from drop down list When stay at the drop down list Delete Group will be unavailable Dele...

Страница 37: ...temporary and user must go back to main tab and presses Save to complete group adding The setting will not be prevailing if user pressed Cancel button at main tab Setup Click Setup the window will pop...

Страница 38: ...ack PDU waits after a command is issued before applying power to an outlet Power Off Delay The time that the Rack PDU waits after a command is issued before removing power from an outlet Default You m...

Страница 39: ...se the action for device with one of On Off Reboot or Short on SNMP Trap mane The Name shows up when sending alarm Chinese is not accessible please think a warming name yourself Monitor Check to comma...

Страница 40: ...con X it would pop up a confirm window your condition would be delete to command device please reset the command Add new name Before setting condition be sure you adding new name first Click the greed...

Страница 41: ...ing Conditions You may command the device with On Off Reboot or Short On go with the condition that had already set Example one If External Humid value set larger than 40 40 and last 2sce Duration 2se...

Страница 42: ...and last 2sce Duration 2sec then it will perform action Off Condition two If External Temp value set larger than 45 45 and last 3sce Duration 3sec then it will perform action Off All of the new added...

Страница 43: ...an be copied to other lines of power outlet Parameter drop down menu allow to copy parameters such as power source setting safe shutdown work schedule network detection current monitoring and peripher...

Страница 44: ...U Status Normal Connected and not monitor Warning Not warning Disconnected and Disconnected and not monitor Monitor Normal Offline Monitor is checked And external temperature is not higher than High A...

Страница 45: ...ay following information RCI cabinet cooling index is now divided into 4 states Cooling percentage100 Desirable Cooling percentage 95 100 Good Cooling percentage 90 95 Acceptable Cooling percentage le...

Страница 46: ...Name The name of temperature sensor High Alarm Set up the values of high temperature alarm When temperature is higher than you set the alarm will occur Low Alarm Set up the values of low temperature...

Страница 47: ...tate Temperature sensor has 6 states Monitor Normal Monitor Alert Monitor Off line the Non monitor Normal Non monitor Alert Non monitor Off line Monitor Normal Offline Monitor is checked And external...

Страница 48: ...is checked And external temperature is not higher than High Alarm or lower than Low Alarm setting Monitor Alert Offline Monitor is checked And external temperature is higher than High Alarm or lower...

Страница 49: ...ow User can set up device name warning humidity and checkbox to enable monitor function or if not disable it Press Save to store configuration Name The name of humidity sensor High RH Alarm Set up the...

Страница 50: ...on of the input detection status The conditions are Normal Warning and Alarm Normal The input status is the same as default Warning The input status is not the same as default but did not exceed the t...

Страница 51: ...low Name Detector name Idle Time sec The setting will set back to default and cause an alarm as the time sec of input detection exceed the idle time you set Default The action to implement when abnorm...

Страница 52: ...abnormality detected UPS tap should be turn on so as its function shows up Go to system Serial Port UPS Turn on UPS functions To let the functions show up please go to system Serial Port UPS and do a...

Страница 53: ...catenated state of UPS device there are two states normal and offline Normal Offline Version Display the version of current UPS device Serial Number Display the serial number of current UPS device Tem...

Страница 54: ...es Normal Overload Battery Information Battery Replacement Date Displays the battery replacement date of the present UPS device Battery voltage Display the battery voltage of current UPS device Batter...

Страница 55: ...work This page can set up basic info of network Enabled DHCP Use checkbox to enable DHCP It will assign IP address IP Address Assign the Network IP address for the power switch Subnet Mask Set up the...

Страница 56: ...ttps Port Provide browser to communicate by HTTP SSL with smart monitor Ethernet Car Speed Ethernet Card is connected to a network operating at 10 M or 100M Mbps Disable ICMP Response When Disable ICM...

Страница 57: ...of alerts Default is 25 From Address It will show on the sender text entry box as recipients receipt the e mail Subject It will show on the subject text entry box as recipients receipt the mail Autho...

Страница 58: ...em Bellwin Click Test the window will pop up as below Send To Address Enter the Email address for test Contents Enter the message for test Test Test result will be displayed at the black area after pr...

Страница 59: ...rver of ISP supplier or preset SMS server Host Host IP address of SMS Server Transmission Mode Follow ISP suppliers rules to send out short message via GET or POST protocol to sender s server Device N...

Страница 60: ...send the message PASSWORD The password to send the message GSMNUM The number to send the message MSG Message content to show as sending a message IP Device IP to show as sending a message Message For...

Страница 61: ...ake sure this function is normal Click Test the window will pop up as below Phone Number Enter your cell phone number for testing Content Enter the message for testing Test Test result will be display...

Страница 62: ...ing Select the checkbox to enable SNMP Write in Write community Key in passwords for the Community Name fields Default is private SNMP v3 Agent Enabled v3 SNMP Enabled SNMP v3 Agent User name The name...

Страница 63: ...contact displayed on SNMPAgent sysLocation The location displayed on SNMPAgent SnmpTrap Host The Host IP address of SNMP Trap SNMP Trap Port The phase connects to SNMP Trap Default is 162 Authenticati...

Страница 64: ...ick Test the window will pop up as below Host Enter the IP address of SNMP Trap Server for testing Port Enter SNMP Server connect port Default is 162 Authority String The authentication string to acce...

Страница 65: ...Server Default is 514 Press Add button to build new data User can press Delete button to remove exist data Please click Save to store setup data Syslog Test After set up the above info do the referen...

Страница 66: ...to store setup after finished 5 6 IDCView This tab shows IDCView data events IDCView Operation Determine the device only to be operated by IDCView system IDCView Host Address IDCView Event Server IP I...

Страница 67: ...ble Cancel UART function Console Computer connects with the device through RS232 and operates the device through terminal program API other devices can operate the current device through API protocol...

Страница 68: ...the correct model and press Search Data Rate bps Use the drop down list to select 1200 115200 Data Rate Data Use the drop down list with 5 to 8 Bit and select one of them Parity Use the drop down list...

Страница 69: ...emp Scale You can choose either Celsius or Fahrenheit Released Temp Range You may set up threshold temp to avoid floating power triggered warning reaction The warning will be dismissed by system when...

Страница 70: ...nit is counted by kilogram Electricity Bill Setup the cost per kilowatt hour The unit is counted by dollar Already Consumed Setup experimented value to accumulative total data record 5 9 Other In this...

Страница 71: ...up permitted IP or Mac address to access this remote power manager 6 1 IP Filter User can set up permitted IP section in this page Enabled IP Filter It will block out unauthorized IP address to access...

Страница 72: ...d Mac address was built System will reject people who try to access this remote power manager from other Mac addresses Unmark the square and press Save button if you expect to cancel this function All...

Страница 73: ...tup 20 sets max of authorized user accounts It can ADD Modify and Delete the User account 7 1 Add New Account When you click Add browser will pop up a window for you to set Account Password and User T...

Страница 74: ...ermitted but not authorized to change system settings Manage Parameter setting is permitted and controllable switch can be changed Administrator Administrator can manage the whole network 7 2 Outlet A...

Страница 75: ...Bellwin Chapter 7 Account Tab 65 7 3 PDU Authority PDU Authority It is to grant the authority to created user s to manage the controllable PDU by clicking the checkboxes...

Страница 76: ...t Control Use the checkbox to enable the setting When switch operation happened the system will inform you by the method you choose PDU Use the checkbox to enable the setting When abnormal condition o...

Страница 77: ...larm system informed by SMS Cellphone Informed by short message please fill the right cellphone number Parameter Use the checkbox to enable the setting The system will follow the warning method you ch...

Страница 78: ...ning message to manager Input Use the checkbox to enable the setting As an abnormal input occurred system will send out warning message to equipment manager Click Add Alarm after setting 7 6 Modify Ac...

Страница 79: ...Time Server Setting Synchronization with Time Server Select this time method if you want the system time of this power switch to be the same as Greenwich Mean Time GMT Time Server You can build a new...

Страница 80: ...70 Chapter 8 Alarm Bellwin Time Zone The time here is following Greenwich Mean Time as most NTP servers do User must adjust the time to be the same with local time...

Страница 81: ...et device and external temperature and humidity charts and statistic data Category It provides infeed outlet device and external temperature and humidity Click Search you will see the reference date c...

Страница 82: ...asons of such logs Click on icon to list all events by order The meaning of three icons is as Refresh Download and Delete Refresh Click Refresh button to refresh the screen Download Click Download but...

Страница 83: ...b 73 Chapter 11 Upgrade Tab Please download the latest firmware of SH4242 from supplier to process upgrade 11 1 Firmware Upgrade The upgrade procedures as follow 1 Click BROWSE button 2 Select the bin...

Страница 84: ...you press Upgrade Firmware button it will display according to the following state Router will reboot automatically and finish the firmware upgraded Upgrade will finish after 100 seconds The upgrade...

Страница 85: ...Chapter 11 Upgrade Tab 75 11 2 Download Upload Configuration File The Download Configuration procedure 1 Click Download button 2 Select the location to save the file The download file is saved in a bi...

Страница 86: ...11 Upgrade Tab Bellwin The Upload Configuration procedure 1 Click BROWSE button 2 Select the cfg bin file 3 Click Open button 4 Click Upload button 5 Once the Upload is complete device will automatica...

Страница 87: ...Bellwin Chapter 11 Upgrade Tab 77 Note Please do not turn off or reboot during updating The upgrade cannot be processed when the file is not cfg bin file...

Страница 88: ...etting of UART1 see 5 7 UART as for the connection method between UART and computer see 2 1 product installation 12 1 Online Set Use the build in Hyperterminal or similar programs to operate SHH Conso...

Страница 89: ...fter entering finished operation menu will be displayed to control power switch and set network data Operation method of the menu is as follows 1 Press or W can drift the menu drift upward 2 Press or...

Страница 90: ...the menu of OUTLET from the main menu press or D to enter power control operation Move Up and Down keys to move the cursor to the power outlet to be operated When the Outlet is ON press Tab for decid...

Страница 91: ...Bellwin Chapter 11 Upgrade Tab 81 12 3 System Preferences After select the menu of SYS from the main menu press or D to enter System Preferences setting...

Страница 92: ...work connecting with this device Subnet Mask Set the network mask of this device IP Gateway Set the device s external gateway address MAC Display the device s MAC value DoName1 the first domain server...

Страница 93: ...Preferences After select the menu of Account from the main menu press or D to enter System Preferences setting this setting is modifying the system administrator password Account System Admin account...

Страница 94: ...nu of Firewall from the main menu press or D to enter System Preferences setting IP Filter Press Space to enable IP filter or not MAC Filter Press Space to enable MAC filter or not Move the cursor to...

Страница 95: ...erence After select the menu of RELOAD from the main menu press or D to enter the query windows to reload all data if yes press Y then the device will reload network user and firewall data and the dat...

Страница 96: ...Tab Bellwin 12 6 Parameter Saving After select the menu of SAVE from the main menu press or D to enter the query windows to save and reboot the device if yes press Y then the device will save the rev...

Страница 97: ...11 Upgrade Tab 87 12 7 log out After select the menu of LOGOUT from the main menu press or D to enter the query windows if press Y then the terminal program will be logged out and the sign in menu wi...

Страница 98: ...own Installation Bellwin Chapter 13 Safety Shutdown Installation 13 1 Windows Step 1 Perform Safety Shutdown installation of the CD attached to this product Step 2 Followed the instruction to install...

Страница 99: ...Bellwin Chapter 13 Safety Shutdown Installation 89 2 Install screen 2 specify the installation directory press Next 3 Install screen 3 Ready to be installed as per the device model press Next...

Страница 100: ...13 Safety Shutdown Installation Bellwin 4 Install screen 4 Setup has finished press Finish 5 Install Menu 5 reboot the computer after the installation completed and then the program will be applied au...

Страница 101: ...1 Step 3 After the installation completed the taskbar in the lower right corner will display the icon of safe shutdown Step 4 Move the cursor to the icon of safety shutdown click the icon and selectio...

Страница 102: ...nt will be displayed And the fields on the window are explained as follows Interface Select the adapter for SH XXX device on line IP The IP address of computer MAC The MAC address of computer Host Nam...

Страница 103: ...gram before turn off Delay Time When the computer receives SH XXX order of shutdown it will leave unmoved after the delayed time ShutDown Delay Time The time that windows wait to show an alert info wh...

Страница 104: ...down tap plus the period to shut down computer so that it can normally turn off the power eg Setup power off delay with 300 sec delay delivery with 300 sec then the period to turn off computer should...

Страница 105: ...hutdown Installation 95 13 2 Linux Centos Step 1 Please perform Safety Shutdown installation of the CD attached to this product and copy the program dss tar gz to etc catalog Step 2 Decompress tar zxv...

Страница 106: ...96 Chapter 13 Safety Shutdown Installation Bellwin Step 3 Copy dss service to usr lib systemd system catalog...

Страница 107: ...ly get a hostname of linux without register DEVICE_IP IP Address of this device DEVICE_PORT Connected Port of SH Default is 22355 NOTIFY Linux will notify users of the times when PC is about to turn o...

Страница 108: ...r messages format of Log None Do not store up Normal usual Warning Alarm Debug Error the latter embody the messages format of former All of the messages formats are store up in var log digipdu_shutdow...

Страница 109: ...Safety Shutdown Installation 99 Step 6 To immediately perform safety shutdown program please execute service dss start Step 7 Once safety shutdown setting finished open the safety shutdown setting me...

Страница 110: ...wer off Delay in Power tap must longer than Delay Delivery in Safety Shutdown tap plus the period to shut down computer so that it can normally turn off the power eg Setup power off delay with 300 sec...

Страница 111: ...Adapter You may have to assign the packet of device Some version ex Windows 7 can only assign an adapter transferring one packet as a result you may have to assign the adapter in the same domain with...

Страница 112: ...y the info of network edit space instruction is shown as below DHCP Use checkbox to enable DHCP It will assign IP address from DHCP IP Set up the IP address of the device Netmask Net mast of the devic...

Страница 113: ...and release Press in 3 10 second account and password will be set as admin System will add a new account if there s no admin account while the function of IDCView only is canceled Device IP will be au...

Страница 114: ...lue Tag Value Tag Value Tag variable list as below Required optional Tag Description Required dSHid Company Code Required username User s Account Required password User s password Required dstaddr Obj...

Страница 115: ...t for reference DEVICENAME The device name to show as sending a message ACCOUNT The account to send the message PASSWORD The password to send the message GSMNUM The number to send the message MSG Mess...

Страница 116: ...ge format Note Company code dSHid xxxxxx Required User s Account account ACCOUNT Required User s password password PASSWORD Required Cellphone number dstaddr GSMNUM Required Device IP Message content...

Страница 117: ..._kind Control types see Output outlet Control Kind Code Table When control the device through Http Https for the sake of normal operation use Http Https basic authentication method to input the admin...

Страница 118: ...scription 0 Output Outlet off 1 Output Outlet on 2 Output Outlet Switching on 3 Output Outlet Switching off Example To control the power of line 1 of the device with IP 192 168 2 10 http 192 168 2 10...

Страница 119: ...is needed in order to connect with the computer ComPort The pins of RJ45 to DB 9 cable are corresponding to different parts as described below 9 pin D Sub female connector RJ45 connector 45 RJ DB9 Fu...

Страница 120: ...index value reverse Example 02 decimal 00 000 010 binary 00 000 010 11110010 0 xFD hexadecimal 3 Function Description Code Function 01 01H Read ZDH peripheral data 02 02H Read ZDH input power data 03...

Страница 121: ...Infeed Branch 1 Number of input power branch Out Total 1 Number of Output Outlet Out Kind 1 Kind f Output Outlet Inbuilt Temperature Total 1 Number of in build temperature sensor Extend Temperature To...

Страница 122: ...eed Total Current 2 Total current divide it by 10 to get the correct current value Infeed Branch1 Current 1 Branch 1 current divide it by 10 to get the correct current value Infeed Branch2 Current 1 B...

Страница 123: ...Lines Respone Domain Name Bytes Description Function Code 1 Function code 03 H Out Id 1 Number of Lines Out Switch Stataus 1 On off status for the relevant data see Output Outlet Status Code Table Ou...

Страница 124: ...Id 1 Number of Lines Ctrl Kind 1 The types to be controlled for the relevant data see Output outlet Control Kind Code Table Respone Domain Name Bytes Description Function Code 1 Function code 04 H Ou...

Страница 125: ...tlet Temp Reboot Output Outlet Status Code Table Status value Description 0 Output Outlet off 1 Output Outlet on 2 Output Outlet Switching on 3 Output Outlet Switching off Example Control the data of...

Страница 126: ...unction Code 1 Function code 05 H Temperature Id 1 Number of Lines Temperature Negative 1 0 for positive and 1 for negative Temperature Value 2 Temperature value Temperature Unit 1 Units of Temperatur...

Страница 127: ...nction Code 1 Function code 06 H Temperature Id 1 Number of Lines Temperature Negative 1 0 for positive and 1 for negative Temperature Value 2 Temperature value Temperature Unit 1 Units of Temperature...

Страница 128: ...code 07 H RH Id 1 Number of Lines Respone Domain Name Bytes Description Function Code 1 Function code 07 H RH Id 1 Number of Lines RH Value 1 Number of Humidity Err Feedback value Description 1 Packa...

Страница 129: ...heet Product Information Specification NSH Series Power Input Voltage 100 240VAC 47 63Hz Power consumption 50 60 HZ Operating temperature 0 40 Dimension Unit mm 178 x 123 x 44 mm W x D x H Net weight...

Страница 130: ...t other than for its normal or any other cause beyond the range of the intended use Incorrect operations improper installation connected to improper appliance or the damage that repair by anyone other...

Страница 131: ...rights of the modification and upgrade on software and documents and is not liable to inform any party about any modified or updated contents If you hope to know more about information of extended wa...

Отзывы: