ATTENTION: When the humidity rises above the selected value, the automatic
option takes precedence over the manual and the unit cannot then be switched
off using a switch.
The desired humidity level and time delay are set by means of adjusters positioned
on the printed circuit board (Fig.7) and are accessible once the grille (1) is removed.
The humidity is set by the adjuster “% RH”
•
To increase the humidity setting turn anti-clockwise (min.60%).
•
To reduce the humidity setting turn clockwise (max.90%).
The timer is set by the adjuster “T min ”
•
To reduce the “run on” time, turn anti-clockwise (min 1 min).
•
To increase the “run on” time, turn clockwise (max. 20 mins).
•
PROFILE – 150 S, T and HT
These models are all fitted with an automatic shutter. The thermal actuator
takes some seconds to open and close completely.
CLEANING AND MAINTENANCE
IMPORTANT: DISCONNECT FROM THE MAINS SUPPLY BEFORE CARRYING
OUT CLEANING OR MAINTENANCE
To ensure optimum performance from your extract fan, it should be cleaned regularly
by a competent person.
AFTER SALES SERVICE
We recommend you recommend you recommend you do not dismantle or
remove any other parts than those mentioned, as any tampering would automatically
cancel the guarantee. If you detec any fault, contact EnviroVent on 01423 810810.