WIRING

IMPORTANT: ENSURE THAT THE MAINS SUPPLY IS SWITCHED OFF BEFORE

MAKING ELECTRICAL CONNECTIONS.

The PROFILE is an extractor fan designed for a single-phase supply, with voltage and

frequency as indicated on the rating plate of the unit. The units are manufactured with

double insulation (Class ll) and therefore do not require an earth connection.

Once the cable has been introduced through the cable entry point (2), proceed using the

electrical wiring diagram applicable to the selected model as follows:

PROFILE – 150 S

This model uses the following wiring diagrams:

Fig.3.

Fan operating through a light switch.

Fig.4.

Fan operating through an independent switch.

PROFILE – 150 T

Models fitted with adjustable timer.

The timer enables the fan to continue running for the selected period after the switch has

been turned off.

Fig.5.

Fan operating through an independent switch.

Fig.6.

Fan operating through a light switch.

The desired run-on time is selected by means of an adjuster “T” positioned on the printed

circuit board (Fig.8), and is accessible once the grille (1) is removed.

To reduce the run-on time, turn anticlockwise.

To increase the run-on time, turn clockwise.

PROFILE – 150 HT

Models provided with an electronic humidistat, which can be adjusted from 60% to 90%

RH (relative humidity), and with a timer, adjustable between 1 and 20 minutes.

Operation
Case 1: Automatic operation (Fig.

4

).

The humidistat causes the extractor to operate automatically when the humidity level in

the room is higher than the set level. The extractor will stop automatically when the

humidity drops below the selected level and after the selected period, set on the timer.

Case 2: Automatic with manual override.

Automatic operation as in case 1, but with the facility to override the humidistat by means

of the light switch (Fig.6), when the humidity level in the room is lower than the selected

level. In this case, the extractor continues to operate for the period set on the timer, after

the light switch has been switched off.

5

Содержание PROFILE–150S

Страница 1: ...PROFILE 150 Installation and Wiring Instructions...

Страница 2: ...sure that the product corresponds to the one you have ordered and that the detail on the instruction label fulfil your requirements IMPORTANT BE SURE TO HAVE READ AND UNDERSTOOD THESE INSTRUCTIONS BE...

Страница 3: ...INSTALLATION PROFILE 150 Fig 3 Fig 4 Fig 5 Fig 6 Fig 7 Fig 8 Fig 2 Fig 1 L N L N L N L N 60 90 2 20 Hr 60 90 Hr 60 90 t min 2 20 min 2 20 1 2 3 5...

Страница 4: ...hole in chosen position in the panel ceiling or wall The hole for the duct should be angled downwards to prevent rainwater running through the duct into the unit Loosen the screw 4 which holds the gri...

Страница 5: ...ugh a light switch The desired run on time is selected by means of an adjuster T positioned on the printed circuit board Fig 8 and is accessible once the grille 1 is removed To reduce the run on time...

Страница 6: ...kwise max 20 mins PROFILE 150 S T and HT These models are all fitted with an automatic shutter The thermal actuator takes some seconds to open and close completely CLEANING AND MAINTENANCE IMPORTANT D...

Страница 7: ...stated within this booklet In the event of any failure of the fan within two years of supply excluding only wilful or careless damage we will exchange the fan free of charge EnviroVent Ltd EnviroVent...

Страница 8: ...EnviroVent Ltd EnviroVent House Hornbeam Business Park Harrogate Hg2 8PA 01423 810 810 www envirovent com info envirovent com Ref 9023007502...

Отзывы: